Heating performance & equipment details
Ranges include the 602 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16–18 | 602 / 602 |
| EER2 · BTU/Wh | 10–11.7 | 602 / 602 |
| HSPF2 · BTU/Wh | 8.5 | 602 / 602 |
| Cooling capacity · BTU/h | 31,200–34,000 | 602 / 602 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 32,000–34,000 | 602 / 602 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 32,600–34,200 | 602 / 602 |
| Heating capacity at 5°F / −15°C · BTU/h | 26,800–28,200 | 602 / 602 |
| COP at 5°F / −15°C | 2.18–2.38 | 602 / 602 |
| Equipment / loop type | HP - Split System | 602 / 602 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 602 / 602 |
| Compressor staging | Two-stage | 602 / 602 |
| Connected capability | No | 602 / 602 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM48C5CFS1+ furnace: Z8ET080C16LMPS1Cold climate designationAHRI reference: 218699636 | 17.50 | 8.50 | 26800 | 2.34 | EPA 4685326 → |
CTM48C5CFS1+ furnace: Z8VT080C16SMPC1Cold climate designationAHRI reference: 218699628 | 17.50 | 8.50 | 26800 | 2.34 | EPA 4685334 → |
CTM36C5CDS1+ furnace: Z8ET100C16LMPS1Cold climate designationAHRI reference: 218699624 | 17.50 | 8.50 | 28000 | 2.30 | EPA 4685338 → |
CTM36C5CDS1+ furnace: Z8VT100C20SMPC1Cold climate designationAHRI reference: 218699612 | 17.50 | 8.50 | 27600 | 2.28 | EPA 4685350 → |
CTU48C5XFS1+TXV+ furnace: Z8ET100C20LMPS1Cold climate designationAHRI reference: 218699234 | 17.50 | 8.50 | 27000 | 2.34 | EPA 4685716 → |
CTF48C5CFS1+ furnace: Z8ET100C20LMPS1Cold climate designationAHRI reference: 218699230 | 17.50 | 8.50 | 27000 | 2.34 | EPA 4685720 → |
CTU48C5XFS1+TXV+ furnace: Z8VT120C20SMPC1Cold climate designationAHRI reference: 218699226 | 17.50 | 8.50 | 26800 | 2.36 | EPA 4685724 → |
CTF48C5CFS1+ furnace: Z8VT120C20SMPC1Cold climate designationAHRI reference: 218699222 | 17.50 | 8.50 | 26800 | 2.36 | EPA 4685728 → |
CTM48C5CFS1+ furnace: Z8ET120C20LMPS1Cold climate designationAHRI reference: 218699154 | 17.50 | 8.50 | 27000 | 2.34 | EPA 4685788 → |
CTM48C5CFS1+ furnace: Z8VT100C20SMPC1Cold climate designationAHRI reference: 218699106 | 17.50 | 8.50 | 26800 | 2.32 | EPA 4685828 → |
CTM48C5CFS1+ furnace: Z8VT120C20SMPC1Cold climate designationAHRI reference: 218699014 | 17.50 | 8.50 | 26800 | 2.34 | EPA 4685920 → |
CTF36C5CDS1+ furnace: Z8ET100C20LMPS1Cold climate designationAHRI reference: 218698998 | 17.50 | 8.50 | 27800 | 2.30 | EPA 4685936 → |
CTM48C5CFS1+ furnace: Z8ET100C20LMPS1Cold climate designationAHRI reference: 218698942 | 17.50 | 8.50 | 27000 | 2.34 | EPA 4685992 → |
CTM36C5CDS1+ furnace: Z8ET100C20LMPS1Cold climate designationAHRI reference: 218698938 | 17.50 | 8.50 | 27800 | 2.30 | EPA 4685996 → |
CTM48C5CFS1+ furnace: Z8VT100C16SMPC1Cold climate designationAHRI reference: 218698914 | 17.50 | 8.50 | 26800 | 2.32 | EPA 4686020 → |
CTM36C5CDS1+ furnace: Z8VT080C16SMPC1Cold climate designationAHRI reference: 218698902 | 17.50 | 8.50 | 27600 | 2.28 | EPA 4686032 → |
CTF36C5CDS1+ furnace: Z8ET120C20LMPS1Cold climate designationAHRI reference: 218698898 | 17.50 | 8.50 | 27200 | 2.24 | EPA 4686036 → |
CTF36C5CDS1+ furnace: Z8VT100C20SMPC1Cold climate designationAHRI reference: 218698890 | 17.50 | 8.50 | 27600 | 2.28 | EPA 4686044 → |
CTF36C5CDS1+ furnace: Z8VT080C16SMPC1Cold climate designationAHRI reference: 218698870 | 17.50 | 8.50 | 27600 | 2.28 | EPA 4686064 → |
CTU48C5XFS2+TXV+ furnace: Z8ES080C20LMPS1Cold climate designationAHRI reference: 218644386 | 17.00 | 8.50 | 27000 | 2.34 | EPA 4665789 → |