ECOER / AIR-SOURCE HEAT PUMP

EODA19H-2436AB*

TDi Pro 2 · source records, page 2

56 published source records · source checked Sep 21, 2026

SEER2 range15.2–20BTU/Wh
HSPF2 range8.3–10BTU/Wh
Cooling capacity22,600–34,200BTU/h

Each efficiency range summarizes published EPA records for EODA19H-2436AB*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 56 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–2056 / 56
EER2 · BTU/Wh10.2–1356 / 56
HSPF2 · BTU/Wh8.3–1056 / 56
Cooling capacity · BTU/h22,600–34,20056 / 56
Heating capacity at 47°F / 8.3°C · BTU/h23,000–36,00056 / 56
Heating capacity at 17°F / −8.3°C · BTU/h18,200–28,80056 / 56
Heating capacity at 5°F / −15°C · BTU/h17,200–25,20056 / 56
COP at 5°F / −15°C1.8–2.156 / 56
Equipment / loop typeHP - Split System56 / 56
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)56 / 56
Compressor stagingContinuously variable56 / 56
Connected capabilityNo56 / 56

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EBCT3036BB*+ furnace: MGV96U080B3CCold climate designationAHRI reference: 21798990218.008.80244001.95EPA 4515685
EBCT3036BB*+ furnace: MGV96U060B3CCold climate designationAHRI reference: 21798990318.008.80244001.95EPA 4515686
EBCT4248CB*+ furnace: MGV96U080C4CAHRI reference: 21798990418.008.70228001.95EPA 4515687
EBCT2430BB*+ furnace: EVMF98M28080B3LCold climate designationAHRI reference: 21799828718.009.00194002.10EPA 4515785
EBCT3036BB*+ furnace: EVMF98M28080B3LCold climate designationAHRI reference: 21799828818.009.00244001.95EPA 4515786
EBCT4248CB*+ furnace: EVMF98M35100C5LAHRI reference: 21799828918.009.00228001.95EPA 4515787
EACE2430BE*+ furnace: EVMF98M28080B3LCold climate designationAHRI reference: 21800423217.509.00194002.05EPA 4515816
EACE3036BE*+ furnace: EVMF98M28080B3LCold climate designationAHRI reference: 21800423317.509.00244001.95EPA 4515817
EACE4248CE*+ furnace: EVMF98M35100C5LCold climate designationAHRI reference: 21800423417.509.00240001.95EPA 4515818
EACE3036BE*+ furnace: MGV80M060B4ACold climate designationAHRI reference: 21806697117.509.00244001.95EPA 4524029
EACE3036BE*+ furnace: MGV80M080B4ACold climate designationAHRI reference: 21806697017.509.00244001.95EPA 4524030
EACE2430BE*+ furnace: MGV80M060B4ACold climate designationAHRI reference: 21806696917.509.00194002.05EPA 4524031
EACE2430BE*+ furnace: MGV80M080B4ACold climate designationAHRI reference: 21806696817.509.00194002.05EPA 4524032
EACE4248CE*+ furnace: MGV96U080C4CCold climate designationAHRI reference: 21806696317.508.80240001.95EPA 4524037
EACE3036BE*+ furnace: MGV96U060B3CCold climate designationAHRI reference: 21806696217.509.00244001.95EPA 4524038
EACE3036BE*+ furnace: MGV96U080B3CCold climate designationAHRI reference: 21806696117.509.00244001.95EPA 4524039
EACE2430BE*+ furnace: MGV96U060B3CCold climate designationAHRI reference: 21806696017.509.00194002.05EPA 4524040
EACE2430BE*+ furnace: MGV96U080B3CCold climate designationAHRI reference: 21806695917.509.00194002.05EPA 4524041
EBCT4248CB*+ furnace: MGH96M100C5AAHRI reference: 21759604317.008.70228001.95EPA 4497833
EBCT2430AB*+ furnace: FG7SA-054C-T23A*Cold climate designationAHRI reference: 21759606217.008.50192002.00EPA 4497849

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →