DuraSTAR / AIR-SOURCE HEAT PUMP

DRU1U18S2A

DRU Series

8 published source records · source checked Sep 21, 2026

SEER2 range16.1–18.8BTU/Wh
HSPF2 range8.2–9.4BTU/Wh
Cooling capacity18,000BTU/h

Each efficiency range summarizes published EPA records for DRU1U18S2A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 8 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16.1–18.88 / 8
EER2 · BTU/Wh11–11.58 / 8
HSPF2 · BTU/Wh8.2–9.48 / 8
Cooling capacity · BTU/h18,0008 / 8
Heating capacity at 47°F / 8.3°C · BTU/h18,000–19,0008 / 8
Heating capacity at 17°F / −8.3°C · BTU/h11,000–12,6008 / 8
Heating capacity at 5°F / −15°C · BTU/h10,000–11,4008 / 8
COP at 5°F / −15°C1.8–2.18 / 8
Equipment / loop typeHP - Split System8 / 8
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)8 / 8
Compressor stagingContinuously variable8 / 8
Connected capabilityNo8 / 8

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
DRUM1824S2AAHRI reference: 21537489218.809.10112002.00EPA 4479500
DRUF1820S2AAHRI reference: 21728507518.509.40114002.10EPA 4479501
DRUC2417S2A+ furnace: ML193DF070XE36B*AHRI reference: 21807225917.708.30100001.80EPA 4569472
DRUC2414S2A+ furnace: RL18060A12MPS1AHRI reference: 21807206017.008.20100001.80EPA 4569504
DRUC2417S2A+ furnace: MGV96U060B3CAHRI reference: 21807172616.408.40100001.90EPA 4569639
DRUC2417S2A+ furnace: RL18080B12MPS1AHRI reference: 21807206116.208.30100001.90EPA 4569503
DRUC2414S2A+ furnace: RL18040A12MPS1AHRI reference: 21807205916.108.20100001.80EPA 4569505
DRUC2417S2A+ furnace: MGV96U080B3CAHRI reference: 21807172716.108.40100001.90EPA 4569638

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.