DuraSTAR / AIR-SOURCE HEAT PUMP

DRU1H24S2A

DRU Series

53 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.4BTU/Wh
HSPF2 range8.5–10.5BTU/Wh
Cooling capacity23,000–24,000BTU/h

Each efficiency range summarizes published EPA records for DRU1H24S2A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 53 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.453 / 53
EER2 · BTU/Wh10–11.753 / 53
HSPF2 · BTU/Wh8.5–10.553 / 53
Cooling capacity · BTU/h23,000–24,00053 / 53
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,00053 / 53
Heating capacity at 17°F / −8.3°C · BTU/h18,000–20,80053 / 53
Heating capacity at 5°F / −15°C · BTU/h19,600–21,60053 / 53
COP at 5°F / −15°C1.75–1.9653 / 53
Equipment / loop typeHP - Split System53 / 53
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)53 / 53
Compressor stagingContinuously variable53 / 53
Connected capabilityNo53 / 53

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
DRUC2417S2A+ furnace: RG19080B12MPS1Cold climate designationAHRI reference: 21807201118.409.90210001.90EPA 4569527
DRUM1824S2ACold climate designationAHRI reference: 21537488518.3010.00216001.87EPA 3624745
DRUC2417S2A+ furnace: MGV96U060B3CCold climate designationAHRI reference: 21807173717.809.20200001.90EPA 4569628
DRUC2414S2A+ furnace: RL18060A12MPS1Cold climate designationAHRI reference: 21807206617.709.40210001.80EPA 4569498
DRUC2414S2A+ furnace: GR9T960403ANCold climate designationAHRI reference: 21807229117.609.10210001.80EPA 4569440
DRUC2417S2A+ furnace: MGV96U080B3CCold climate designationAHRI reference: 21807173817.609.30200001.90EPA 4569627
DRUF2420S2ACold climate designationAHRI reference: 21746540717.5010.50196001.96EPA 4437909
DRUC2414S2A+ furnace: RG19040A10MPS1Cold climate designationAHRI reference: 21807200817.508.80200001.80EPA 4569530
DRUC2414S2A+ furnace: GR9T960303ANCold climate designationAHRI reference: 21807229017.409.20210001.80EPA 4569441
DRUC2417S2A+ furnace: S9V2B060D3VS***Cold climate designationAHRI reference: 21807171417.208.50200001.80EPA 4569651
DRUC2417S2A+ furnace: S9V2B060U4VS***Cold climate designationAHRI reference: 21807171317.208.50200001.80EPA 4569652
DRUC2417S2A+ furnace: S9V2B040U3VS***Cold climate designationAHRI reference: 21807171217.208.50200001.80EPA 4569653
DRUC2414S2A+ furnace: GR9S920403ANCold climate designationAHRI reference: 21807228417.109.10200001.80EPA 4569447
DRUC2417S2A+ furnace: RL18080B12MPS1Cold climate designationAHRI reference: 21807206717.109.30200001.90EPA 4569497
DRUC2417S2A+ furnace: S9V2B080D4VS***Cold climate designationAHRI reference: 21807182417.109.10200001.80EPA 4569595
DRUC2417S2A+ furnace: S9V2B040D3VS***Cold climate designationAHRI reference: 21807182317.109.00200001.80EPA 4569596
DRUC2417S2A+ furnace: GD9S960603BNCold climate designationAHRI reference: 21807229617.009.30200001.80EPA 4569435
DRUC2417S2A+ furnace: ML193DF070XE36B*Cold climate designationAHRI reference: 21807226617.009.10200001.80EPA 4569465
DRUC2417S2A+ furnace: ML193DF045XE36B*Cold climate designationAHRI reference: 21807226516.909.00200001.75EPA 4569466
DRUC2414S2A+ furnace: RL18040A12MPS1Cold climate designationAHRI reference: 21807206516.909.20200001.80EPA 4569499

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →