DuraSTAR / AIR-SOURCE HEAT PUMP

DRHP15B60AJ2AN

DRAC

9 published source records · source checked Sep 21, 2026

SEER2 range15.2BTU/Wh
HSPF2 range7.8BTU/Wh
Cooling capacity55,500–57,000BTU/h

Each efficiency range summarizes published EPA records for DRHP15B60AJ2AN. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 9 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.29 / 9
EER2 · BTU/Wh11.79 / 9
HSPF2 · BTU/Wh7.89 / 9
Cooling capacity · BTU/h55,500–57,0009 / 9
Heating capacity at 47°F / 8.3°C · BTU/h55,000–56,0009 / 9
Heating capacity at 17°F / −8.3°C · BTU/h35,400–55,0009 / 9
Heating capacity at 5°F / −15°C · BTU/h25,000–25,4008 / 9
COP at 5°F / −15°C2–2.18 / 9
Equipment / loop typeHP - Split System9 / 9
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)9 / 9
Compressor stagingTwo-stage9 / 9
Connected capabilityNo9 / 9

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
DRAH2TB6024ASTNNAHRI reference: 21541548815.207.80EPA 3624758
DRBEF6024STANMC+ furnace: DR80UHAW1251524AHRI reference: 21668689915.207.80250002.00EPA 4513664
DRBEF6024STANMC+ furnace: DR80UHAW1001521SAHRI reference: 21668690015.207.80254002.00EPA 4513665
DRBEF6024STANMC+ furnace: DR80UHAW1001521NAHRI reference: 21668690415.207.80254002.00EPA 4513666
DRBEF6024STANMC+ furnace: DR80UHAW1002521AHRI reference: 21668690515.207.80254002.00EPA 4513667
DRBEF6021STAAMC+ furnace: DR80UHAW1001521SAHRI reference: 21668697715.207.80250002.10EPA 4513717
DRBEF6021STAAMC+ furnace: DR80UHAW1001521NAHRI reference: 21668697915.207.80250002.10EPA 4513718
DRBEF6021STAAMC+ furnace: DR80UHAW1002521AHRI reference: 21668698115.207.80250002.10EPA 4513719
DRBEF6024STANMC+ furnace: DR80UHAW1252524AHRI reference: 21668710715.207.80250002.00EPA 4513726

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →