DRHP15B42AJ2AN
DRAC · source records, page 2
50 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for DRHP15B42AJ2AN. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 50 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 50 / 50 |
| EER2 · BTU/Wh | 11.7 | 50 / 50 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 50 / 50 |
| Cooling capacity · BTU/h | 40,000 | 50 / 50 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 40,000 | 50 / 50 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 27,000–40,000 | 50 / 50 |
| Heating capacity at 5°F / −15°C · BTU/h | 18,700–19,300 | 49 / 50 |
| COP at 5°F / −15°C | 2 | 49 / 50 |
| Equipment / loop type | HP - Split System | 50 / 50 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 50 / 50 |
| Compressor staging | Two-stage | 50 / 50 |
| Connected capability | No | 50 / 50 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
DRBEF4821STANMC+ furnace: DR80UHAW0751417Cold climate designationAHRI reference: 216686815 | 15.20 | 8.10 | 18800 | 2.00 | EPA 4009893 → |
DRBEF4824STANMC+ furnace: DR80UHAW1001521NCold climate designationAHRI reference: 216686824 | 15.20 | 8.10 | 18800 | 2.00 | EPA 4009894 → |
DRBEF4824STANMC+ furnace: DR80UHAW0751521Cold climate designationAHRI reference: 216686830 | 15.20 | 8.10 | 18900 | 2.00 | EPA 4009895 → |
DRBEF4824STANMC+ furnace: DR80DZAW1252524Cold climate designationAHRI reference: 216686827 | 15.20 | 8.10 | 18700 | 2.00 | EPA 4009896 → |
DRBEF4824STANMC+ furnace: DR80UHAW0752521Cold climate designationAHRI reference: 216686821 | 15.20 | 8.10 | 18900 | 2.00 | EPA 4009897 → |
DRBEF4821STANMC+ furnace: DR80UHAW1002521Cold climate designationAHRI reference: 216686828 | 15.20 | 8.10 | 18800 | 2.00 | EPA 4009898 → |
DRBEF4824STANMC+ furnace: DR80DZAW1002521Cold climate designationAHRI reference: 216686823 | 15.20 | 8.10 | 18700 | 2.00 | EPA 4009899 → |
DRBEF4824STANMC+ furnace: DR80DZAW1001521Cold climate designationAHRI reference: 216686822 | 15.20 | 8.10 | 18700 | 2.00 | EPA 4009900 → |
DRBEF4824STANMC+ furnace: DR80UHAW1502524Cold climate designationAHRI reference: 216686826 | 15.20 | 8.10 | 18800 | 2.00 | EPA 4009901 → |
DRBEF4821STANMC+ furnace: DR80DZAW1002521Cold climate designationAHRI reference: 216686835 | 15.20 | 8.10 | 18700 | 2.00 | EPA 4009902 → |
DRBEF4821STANMC+ furnace: DR80DZAW0751417Cold climate designationAHRI reference: 216686833 | 15.20 | 8.10 | 19300 | 2.00 | EPA 4009903 → |
DRBEF4824STANMC+ furnace: DR80UHAW1251524Cold climate designationAHRI reference: 216686832 | 15.20 | 8.10 | 18800 | 2.00 | EPA 4009904 → |
DRBEF4821STANMC+ furnace: DR80UHAW0752521Cold climate designationAHRI reference: 216686834 | 15.20 | 8.10 | 18900 | 2.00 | EPA 4009905 → |
DRBEF4821STANMC+ furnace: DR80UHAW1001521NCold climate designationAHRI reference: 216686836 | 15.20 | 8.10 | 18800 | 2.00 | EPA 4009906 → |
DRBEF4821STANMC+ furnace: DR80DZAW0752521Cold climate designationAHRI reference: 216686837 | 15.20 | 8.10 | 18800 | 2.00 | EPA 4009907 → |
DRBEF4821STANMC+ furnace: DR80UHAW1002417Cold climate designationAHRI reference: 216686831 | 15.20 | 8.10 | 19000 | 2.00 | EPA 4009908 → |
DRBEF4824STANMC+ furnace: DR80DZAW0752521Cold climate designationAHRI reference: 216686838 | 15.20 | 8.10 | 18800 | 2.00 | EPA 4009909 → |
DRBEF4821STANMC+ furnace: DR80DZAW0751521Cold climate designationAHRI reference: 216686844 | 15.20 | 8.10 | 18800 | 2.00 | EPA 4009910 → |
DRBEF4821STANMC+ furnace: DR80DZAW1001521Cold climate designationAHRI reference: 216686842 | 15.20 | 8.10 | 18700 | 2.00 | EPA 4009911 → |
DRBEF4821STANMC+ furnace: DR80UHAW1001417Cold climate designationAHRI reference: 216686840 | 15.20 | 8.10 | 19000 | 2.00 | EPA 4009912 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →