DuraSTAR / AIR-SOURCE HEAT PUMP

DRHP15B36AJ2AN

DRAC

56 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8BTU/Wh
Cooling capacity34,200BTU/h

Each efficiency range summarizes published EPA records for DRHP15B36AJ2AN. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 56 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1656 / 56
EER2 · BTU/Wh11.756 / 56
HSPF2 · BTU/Wh7.856 / 56
Cooling capacity · BTU/h34,20056 / 56
Heating capacity at 47°F / 8.3°C · BTU/h33,200–34,20056 / 56
Heating capacity at 17°F / −8.3°C · BTU/h23,400–33,20056 / 56
Heating capacity at 5°F / −15°C · BTU/h18,100–18,90055 / 56
COP at 5°F / −15°C2–2.155 / 56
Equipment / loop typeHP - Split System56 / 56
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)56 / 56
Compressor stagingTwo-stage56 / 56
Connected capabilityNo56 / 56

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
DRF2TB3624ASTSNAHRI reference: 21668706116.007.80181002.10EPA 4513720 →
DRBEF3621STANMC+ furnace: DR80UHAW1001521UAHRI reference: 21668710516.007.80184002.00EPA 4513725 →
DRAH2TB3617ASTNNAHRI reference: 21541548715.207.80——EPA 3624760 →
DRBEF3621STANMC+ furnace: DR95UHAW1001521AHRI reference: 21668695915.207.80185002.00EPA 4510615 →
DRBEF3621STANMC+ furnace: DR80DZAW0751521AHRI reference: 21668691915.207.80183002.00EPA 4513668 →
DRBEF3621STANMC+ furnace: DR80DZAW1001521AHRI reference: 21668692015.207.80182002.00EPA 4513669 →
DRBEF3617STANMC+ furnace: DR80UHAW0751417AHRI reference: 21668692115.207.80183002.00EPA 4513670 →
DRBEF3621STANMC+ furnace: DR80UHAW0501417SAHRI reference: 21668692215.207.80189002.00EPA 4513671 →
DRBEF3621STANMC+ furnace: DR80UHAW1001521SAHRI reference: 21668692315.207.80183002.00EPA 4513672 →
DRBEF3617STANMC+ furnace: DR80DZAW0751417AHRI reference: 21668692415.207.80186002.00EPA 4513673 →
DRBEF3617STANMC+ furnace: DR80UHAW0501314AHRI reference: 21668692515.207.80186002.00EPA 4513674 →
DRBEF3617STANMC+ furnace: DR80UHAW1001417AHRI reference: 21668692615.207.80184002.00EPA 4513675 →
DRBEF3617STANMC+ furnace: DR80UHAW0501417NAHRI reference: 21668692715.207.80189002.00EPA 4513676 →
DRBEF3617STANMC+ furnace: DR80DZAW0501314AHRI reference: 21668692815.207.80184002.00EPA 4513677 →
DRBEF3621STANMC+ furnace: DR80UHAW0751521AHRI reference: 21668692915.207.80184002.00EPA 4513678 →
DRBEF3621STANMC+ furnace: DR80UHAW1001417AHRI reference: 21668693015.207.80184002.00EPA 4513679 →
DRBEF3617STANMC+ furnace: DR80UHAW0501417SAHRI reference: 21668693115.207.80189002.00EPA 4513680 →
DRBEF3621STANMC+ furnace: DR80UHAW0751417AHRI reference: 21668693215.207.80183002.00EPA 4513681 →
DRBEF3621STANMC+ furnace: DR80UHAW1001521NAHRI reference: 21668693315.207.80183002.00EPA 4513682 →
DRBEF3621STANMC+ furnace: DR80DZAW0751417AHRI reference: 21668693415.207.80186002.00EPA 4513683 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →