7SCP18V60P-**A
7SCP18V Series · source records, page 7
191 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 7SCP18V60P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 191 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 191 / 191 |
| EER2 · BTU/Wh | 9.6–11.7 | 191 / 191 |
| HSPF2 · BTU/Wh | 8.1–9.6 | 191 / 191 |
| Cooling capacity · BTU/h | 42,500–55,500 | 191 / 191 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–56,500 | 191 / 191 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,500–45,000 | 191 / 191 |
| Heating capacity at 5°F / −15°C · BTU/h | 39,000–45,000 | 191 / 191 |
| COP at 5°F / −15°C | 1.75–1.95 | 191 / 191 |
| Equipment / loop type | HP - Split System | 191 / 191 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 191 / 191 |
| Compressor staging | Continuously variable | 191 / 191 |
| Connected capability | No | 191 / 191 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
7ED42BX-**+TDR+ furnace: 97G2DF070BE16*Cold climate designationAHRI reference: 217450715 | 16.15 | 9.00 | 39500 | 1.85 | EPA 4046422 → |
7ED60DX-**+TDR+ furnace: 97G2DF110CE20*Cold climate designationAHRI reference: 217450733 | 16.15 | 8.50 | 40500 | 1.90 | EPA 4046508 → |
7EH42CX-**+TDR+ furnace: 97G2UH090CV20*Cold climate designationAHRI reference: 216769781 | 16.10 | 8.50 | 40000 | 1.80 | EPA 3984011 → |
7E[C,U]48CX-**+TDR+ furnace: 97G2UH110CE20*Cold climate designationAHRI reference: 217450690 | 16.10 | 8.50 | 40000 | 1.80 | EPA 4046264 → |
7EH50/60CX-**+TDR+ furnace: 97G2UH110CE20*Cold climate designationAHRI reference: 217450728 | 16.10 | 8.50 | 40500 | 1.85 | EPA 4046461 → |
7ED50/60CX-**+TDR+ furnace: 97G2DF110CE20*Cold climate designationAHRI reference: 217450731 | 16.10 | 8.50 | 40500 | 1.90 | EPA 4046463 → |
7EH51CX-**+TDR+ furnace: 97G2UH110CE20*Cold climate designationAHRI reference: 217897373 | 16.10 | 8.50 | 40500 | 1.85 | EPA 4512294 → |
7EH50/60CX-**+TDR+ furnace: 97G2UH090CV20*Cold climate designationAHRI reference: 216769815 | 16.05 | 8.50 | 40500 | 1.85 | EPA 3983776 → |
7EH50/60CX-**+TDR+ furnace: 96G1UH110CE20*Cold climate designationAHRI reference: 217189619 | 16.05 | 8.50 | 41000 | 1.85 | EPA 4007812 → |
7EH51CX-**+TDR+ furnace: 96G1UH110CE20*Cold climate designationAHRI reference: 217897367 | 16.05 | 8.50 | 41000 | 1.85 | EPA 4512287 → |
7EH51CX-**+TDR+ furnace: 97G2UH090CV20*Cold climate designationAHRI reference: 217897370 | 16.05 | 8.50 | 40500 | 1.85 | EPA 4512291 → |
7AH1AV60PX-**Cold climate designationAHRI reference: 216013471 | 16.00 | 9.40 | 43000 | 1.75 | EPA 3801685 → |
7EH48CX-**+TDR+ furnace: 97G2UH110CV20*Cold climate designationAHRI reference: 216769783 | 16.00 | 8.50 | 40000 | 1.80 | EPA 3983685 → |
7ED42BX-**+TDR+ furnace: 97G2DF070BV16*Cold climate designationAHRI reference: 216769785 | 16.00 | 9.00 | 40000 | 1.85 | EPA 3983687 → |
7ED60DX-**+TDR+ furnace: 97G2DF110CV20*Cold climate designationAHRI reference: 216769821 | 16.00 | 8.50 | 41000 | 1.90 | EPA 3984004 → |
7ED60DX-**+TDR+ furnace: 97G2DF090CV20*Cold climate designationAHRI reference: 216769819 | 16.00 | 8.50 | 40500 | 1.90 | EPA 3984023 → |
7EH48CX-**+TDR+ furnace: 95G1UH080CE16X*Cold climate designationAHRI reference: 217189595 | 16.00 | 8.50 | 39500 | 1.80 | EPA 4007442 → |
7EH48CX-**+TDR+ furnace: 80G1UH090CE20*Cold climate designationAHRI reference: 217189598 | 16.00 | 8.50 | 39500 | 1.80 | EPA 4007445 → |
7EH48CX-**+TDR+ furnace: 80G1UH110CE20*Cold climate designationAHRI reference: 217189599 | 16.00 | 8.50 | 40000 | 1.80 | EPA 4007446 → |
7E[C,U]60CX-**+TDR+ furnace: 80G1UH100CE20X*Cold climate designationAHRI reference: 217189605 | 16.00 | 8.50 | 40500 | 1.90 | EPA 4007628 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.