7SCP18V60P-**A
7SCP18V Series · source records, page 5
191 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 7SCP18V60P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 191 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 191 / 191 |
| EER2 · BTU/Wh | 9.6–11.7 | 191 / 191 |
| HSPF2 · BTU/Wh | 8.1–9.6 | 191 / 191 |
| Cooling capacity · BTU/h | 42,500–55,500 | 191 / 191 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–56,500 | 191 / 191 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,500–45,000 | 191 / 191 |
| Heating capacity at 5°F / −15°C · BTU/h | 39,000–45,000 | 191 / 191 |
| COP at 5°F / −15°C | 1.75–1.95 | 191 / 191 |
| Equipment / loop type | HP - Split System | 191 / 191 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 191 / 191 |
| Compressor staging | Continuously variable | 191 / 191 |
| Connected capability | No | 191 / 191 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
7E[C,U]49CX-**+TDR+ furnace: 80G2UH110CE20L*Cold climate designationAHRI reference: 217189574 | 16.55 | 9.00 | 39000 | 1.85 | EPA 4007531 → |
7E[C,U]49CX-**+TDR+ furnace: 80G2UH110CE20*Cold climate designationAHRI reference: 217189575 | 16.55 | 9.00 | 39000 | 1.85 | EPA 4007532 → |
7E[C,U]49CX-**+TDR+ furnace: 92G1UH110CE20*Cold climate designationAHRI reference: 217450698 | 16.55 | 9.00 | 39500 | 1.85 | EPA 4046215 → |
7ED48CX-**+TDR+ furnace: 97G2DF090CV20*Cold climate designationAHRI reference: 216769787 | 16.50 | 9.00 | 40000 | 1.85 | EPA 3983689 → |
7E[C,U]60CX-**+TDR+ furnace: 96G1UH110CE20*Cold climate designationAHRI reference: 217189611 | 16.50 | 8.50 | 40500 | 1.90 | EPA 4007524 → |
7E[C,U]60CX-**+TDR+ furnace: 80G2UH110CV20*Cold climate designationAHRI reference: 217189604 | 16.50 | 8.50 | 40500 | 1.90 | EPA 4007627 → |
7EH42CX-**+TDR+ furnace: 95G1UH080CE16X*Cold climate designationAHRI reference: 217189585 | 16.50 | 8.50 | 39500 | 1.80 | EPA 4007798 → |
7EH48CX-**+TDR+ furnace: 92G1UH110CE16*Cold climate designationAHRI reference: 217450711 | 16.45 | 8.50 | 39500 | 1.80 | EPA 4046418 → |
7EH60DX-**+TDR+ furnace: 97G2UH135DV20*Cold climate designationAHRI reference: 216769825 | 16.40 | 8.50 | 40500 | 1.85 | EPA 3983653 → |
7E[C,U]60CX-**+TDR+ furnace: 95G1UH100CE20X*Cold climate designationAHRI reference: 217189610 | 16.40 | 8.50 | 40500 | 1.90 | EPA 4007523 → |
7ED48CX-**+TDR+ furnace: 96G1DF110CE20*Cold climate designationAHRI reference: 217450719 | 16.40 | 9.00 | 39500 | 1.90 | EPA 4046296 → |
7EH42CX-**+TDR+ furnace: 97G2UH110CV20*Cold climate designationAHRI reference: 216769779 | 16.35 | 8.50 | 39500 | 1.80 | EPA 3983565 → |
7EH50/60CX-**+TDR+ furnace: 97G2UH110CV20*Cold climate designationAHRI reference: 216769813 | 16.35 | 8.50 | 40500 | 1.85 | EPA 3984020 → |
7E[C,U]48BX-**+TDR+ furnace: 80G1UH080BE16X*Cold climate designationAHRI reference: 217189558 | 16.35 | 8.50 | 39500 | 1.80 | EPA 4007327 → |
7EH48CX-**+TDR+ furnace: 80G2UH110CV20*Cold climate designationAHRI reference: 217189597 | 16.35 | 8.50 | 40000 | 1.80 | EPA 4007444 → |
7EH51CX-**+TDR+ furnace: 97G2UH110CV20*Cold climate designationAHRI reference: 217897376 | 16.35 | 8.50 | 40500 | 1.85 | EPA 4512352 → |
7E[C,U]48CX-**+TDR+ furnace: 80G1UH100CE20X*Cold climate designationAHRI reference: 217189565 | 16.30 | 8.50 | 40000 | 1.80 | EPA 4007754 → |
7EH48BX-**+TDR+ furnace: 80G1UH080BE16X*Cold climate designationAHRI reference: 217189591 | 16.30 | 9.00 | 39500 | 1.80 | EPA 4007804 → |
7EH50/60CX-**+TDR+ furnace: 80G2UH110CE20L*Cold climate designationAHRI reference: 217189614 | 16.30 | 8.50 | 40000 | 1.85 | EPA 4007807 → |
7EH50/60CX-**+TDR+ furnace: 80G2UH110CE20*Cold climate designationAHRI reference: 217189615 | 16.30 | 8.50 | 40000 | 1.85 | EPA 4007808 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →