7SCP18V60P-**A
7SCP18V Series · source records, page 3
191 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 7SCP18V60P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 191 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 191 / 191 |
| EER2 · BTU/Wh | 9.6–11.7 | 191 / 191 |
| HSPF2 · BTU/Wh | 8.1–9.6 | 191 / 191 |
| Cooling capacity · BTU/h | 42,500–55,500 | 191 / 191 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–56,500 | 191 / 191 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,500–45,000 | 191 / 191 |
| Heating capacity at 5°F / −15°C · BTU/h | 39,000–45,000 | 191 / 191 |
| COP at 5°F / −15°C | 1.75–1.95 | 191 / 191 |
| Equipment / loop type | HP - Split System | 191 / 191 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 191 / 191 |
| Compressor staging | Continuously variable | 191 / 191 |
| Connected capability | No | 191 / 191 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
7EH48BX-**+TDR+ furnace: 80G1UH090BE16L*Cold climate designationAHRI reference: 217450707 | 16.90 | 9.00 | 39500 | 1.85 | EPA 4046432 → |
7E[C,U]49CX-**+TDR+ furnace: 80G1UH100CE20X*Cold climate designationAHRI reference: 217189573 | 16.85 | 9.00 | 39500 | 1.85 | EPA 4007530 → |
7E[C,U]60CX-**+TDR+ furnace: 80G2UH110CE20L*Cold climate designationAHRI reference: 217189606 | 16.85 | 8.50 | 40000 | 1.90 | EPA 4007629 → |
7E[C,U]60CX-**+TDR+ furnace: 80G2UH110CE20*Cold climate designationAHRI reference: 217189607 | 16.85 | 8.50 | 40000 | 1.90 | EPA 4007630 → |
7AH1AE60PX-**Cold climate designationAHRI reference: 216619082 | 16.80 | 9.00 | 43000 | 1.80 | EPA 3893068 → |
7E[C,U]48BX-**+TDR+ furnace: 80G2UH090BE16L*Cold climate designationAHRI reference: 217189559 | 16.80 | 8.50 | 39500 | 1.80 | EPA 4007341 → |
7EH48BX-**+TDR+ furnace: 80G2UH090BE16L*Cold climate designationAHRI reference: 217189592 | 16.80 | 9.00 | 39500 | 1.85 | EPA 4007439 → |
7EH48BX-**+TDR+ furnace: 80G2UH090BE16*Cold climate designationAHRI reference: 217189593 | 16.80 | 9.00 | 39500 | 1.85 | EPA 4007440 → |
7EH42BX-**+TDR+ furnace: 80G2UH090BV16*Cold climate designationAHRI reference: 217189580 | 16.80 | 9.00 | 39000 | 1.90 | EPA 4007673 → |
7EH42BX-**+TDR+ furnace: 80G2UH090BE16L*Cold climate designationAHRI reference: 217189582 | 16.80 | 9.00 | 39000 | 1.90 | EPA 4007675 → |
7EH42BX-**+TDR+ furnace: 80G2UH090BE16*Cold climate designationAHRI reference: 217189583 | 16.80 | 9.00 | 39000 | 1.90 | EPA 4007676 → |
7E[C,U]48BX-**+TDR+ furnace: 80G2UH090BE16*Cold climate designationAHRI reference: 217189560 | 16.80 | 8.50 | 39500 | 1.80 | EPA 4007749 → |
7EH48BX-**+TDR+ furnace: 80G2UH090BV16*Cold climate designationAHRI reference: 217189590 | 16.80 | 9.00 | 39500 | 1.85 | EPA 4007803 → |
7E[C,U]48CX-**+TDR+ furnace: 92G1UH090CE16*Cold climate designationAHRI reference: 217450687 | 16.80 | 8.50 | 39500 | 1.80 | EPA 4046261 → |
7E[C,U]60CX-**+TDR+ furnace: 92G1UH110CE20*Cold climate designationAHRI reference: 217450725 | 16.80 | 8.50 | 40500 | 1.90 | EPA 4046446 → |
7E[C,U]48CX-**+TDR+ furnace: 97G2UH110CV20*Cold climate designationAHRI reference: 216769771 | 16.75 | 8.50 | 39500 | 1.80 | EPA 3983773 → |
7EH42CX-**+TDR+ furnace: 97G2UH090CE16*Cold climate designationAHRI reference: 217450701 | 16.75 | 8.50 | 39500 | 1.80 | EPA 4046426 → |
7EH42CX-**+TDR+ furnace: 92G1UH090CE16*Cold climate designationAHRI reference: 217450702 | 16.75 | 8.50 | 39500 | 1.80 | EPA 4046427 → |
7E[C,U]49CX-**+TDR+ furnace: 96G1UH090CE16*Cold climate designationAHRI reference: 217189571 | 16.70 | 9.00 | 39500 | 1.85 | EPA 4007528 → |
7EH42CX-**+TDR+ furnace: 80G2UH110CV20*Cold climate designationAHRI reference: 217189587 | 16.70 | 8.50 | 39500 | 1.80 | EPA 4007800 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →