7SCP18V36P-**A
7SCP18V Series · source records, page 6
194 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 7SCP18V36P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 194 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18.7 | 194 / 194 |
| EER2 · BTU/Wh | 10–12 | 194 / 194 |
| HSPF2 · BTU/Wh | 8.1–9.6 | 194 / 194 |
| Cooling capacity · BTU/h | 32,200–36,000 | 194 / 194 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 34,000–38,500 | 194 / 194 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 27,000–29,600 | 194 / 194 |
| Heating capacity at 5°F / −15°C · BTU/h | 28,000–30,800 | 194 / 194 |
| COP at 5°F / −15°C | 1.8–1.9 | 194 / 194 |
| Equipment / loop type | HP - Split System | 194 / 194 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 194 / 194 |
| Compressor staging | Continuously variable | 194 / 194 |
| Connected capability | No | 194 / 194 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
7EH30BX-**+TDR+ furnace: 92G1UH045BE12*Cold climate designationAHRI reference: 217450659 | 17.40 | 8.50 | 28600 | 1.85 | EPA 4046200 → |
7ED30/36BX-**+TDR+ furnace: 92G1DF070BE12*Cold climate designationAHRI reference: 217450678 | 17.40 | 8.50 | 28600 | 1.85 | EPA 4046541 → |
7E[C,U]30BX-**+TDR+ furnace: 97G2UH045BE12*Cold climate designationAHRI reference: 217450638 | 17.40 | 8.50 | 28800 | 1.80 | EPA 4046585 → |
7E[C,U]30BX-**+TDR+ furnace: 92G1UH070BE12*Cold climate designationAHRI reference: 217450642 | 17.40 | 8.50 | 28600 | 1.80 | EPA 4046588 → |
7ED30/36BX-***+TDR+ furnace: 92G1DF070BE12*Cold climate designationAHRI reference: 218114549 | 17.40 | 8.50 | 28600 | 1.85 | EPA 4573226 → |
7E[C,U]36BX-**+TDR+ furnace: 97G2UH045BV12*Cold climate designationAHRI reference: 216769719 | 17.35 | 8.50 | 28400 | 1.85 | EPA 3983672 → |
7E[C,U]30BX-**+TDR+ furnace: 95G1UH060BE12X*Cold climate designationAHRI reference: 217189475 | 17.35 | 8.50 | 28600 | 1.80 | EPA 4007288 → |
7ED30/36BX-**+TDR+ furnace: 96G1DF045BE12*Cold climate designationAHRI reference: 217189550 | 17.35 | 8.50 | 28400 | 1.85 | EPA 4007621 → |
7EH30BX-**+TDR+ furnace: 96G1UH045BE12*Cold climate designationAHRI reference: 217189518 | 17.35 | 8.50 | 28400 | 1.85 | EPA 4007710 → |
7EH36BX-**+TDR+ furnace: 92G1UH045BE12*Cold climate designationAHRI reference: 217450668 | 17.35 | 8.50 | 28600 | 1.85 | EPA 4046489 → |
7EH36CX-**+TDR+ furnace: 92G1UH090CE16*Cold climate designationAHRI reference: 217450674 | 17.35 | 9.00 | 28200 | 1.90 | EPA 4046495 → |
7ED30/36BX-***+TDR+ furnace: 96G1DF045BE12*Cold climate designationAHRI reference: 218114534 | 17.35 | 8.50 | 28400 | 1.85 | EPA 4573241 → |
7EH30BX-**+TDR+ furnace: 97G2UH045BV12*Cold climate designationAHRI reference: 216769723 | 17.30 | 8.50 | 28400 | 1.85 | EPA 3983675 → |
7EH36BX-**+TDR+ furnace: 97G2UH045BV12*Cold climate designationAHRI reference: 216769727 | 17.30 | 8.50 | 28400 | 1.85 | EPA 3983723 → |
7E[C,U]30BX-**+TDR+ furnace: 97G2UH070BV12*Cold climate designationAHRI reference: 216769717 | 17.30 | 8.50 | 28400 | 1.85 | EPA 3984008 → |
7E[C,U]36BX-**+TDR+ furnace: 80G1DF090BE16*Cold climate designationAHRI reference: 217189504 | 17.30 | 8.50 | 28200 | 1.90 | EPA 4007278 → |
7ED42BX-**+TDR+ furnace: 80G2DF090BE16*Cold climate designationAHRI reference: 217189555 | 17.30 | 8.50 | 28200 | 1.90 | EPA 4007344 → |
7ED30/36BX-**+TDR+ furnace: 80G1DF070BE12*Cold climate designationAHRI reference: 217189549 | 17.30 | 8.50 | 28400 | 1.85 | EPA 4007620 → |
7E[C,U]30AX-**+TDR+ furnace: 80G2UH070AE12L*Cold climate designationAHRI reference: 217189466 | 17.30 | 8.50 | 28600 | 1.85 | EPA 4007650 → |
7E[C,U]30AX-**+TDR+ furnace: 80G2UH070AE12*Cold climate designationAHRI reference: 217189467 | 17.30 | 8.50 | 28600 | 1.85 | EPA 4007651 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →