7SCP18V36P-**A
7SCP18V Series · source records, page 2
194 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 7SCP18V36P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 194 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18.7 | 194 / 194 |
| EER2 · BTU/Wh | 10–12 | 194 / 194 |
| HSPF2 · BTU/Wh | 8.1–9.6 | 194 / 194 |
| Cooling capacity · BTU/h | 32,200–36,000 | 194 / 194 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 34,000–38,500 | 194 / 194 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 27,000–29,600 | 194 / 194 |
| Heating capacity at 5°F / −15°C · BTU/h | 28,000–30,800 | 194 / 194 |
| COP at 5°F / −15°C | 1.8–1.9 | 194 / 194 |
| Equipment / loop type | HP - Split System | 194 / 194 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 194 / 194 |
| Compressor staging | Continuously variable | 194 / 194 |
| Connected capability | No | 194 / 194 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
7E[C,U]36BX-**+TDR+ furnace: 80G1UH070BE12*Cold climate designationAHRI reference: 217189493 | 18.05 | 8.50 | 28400 | 1.85 | EPA 4007428 → |
7E[C,U]36BX-**+TDR+ furnace: 80G1UH070BE12L*Cold climate designationAHRI reference: 217189494 | 18.05 | 8.50 | 28400 | 1.85 | EPA 4007429 → |
7EH36BX-**+TDR+ furnace: 80G2UH090BV16*Cold climate designationAHRI reference: 217189541 | 18.05 | 8.50 | 28200 | 1.85 | EPA 4007504 → |
7EH30BX-**+TDR+ furnace: 80G2UH090BV16*Cold climate designationAHRI reference: 217189520 | 18.05 | 8.50 | 28200 | 1.85 | EPA 4007541 → |
7E[C,U]36BX-**+TDR+ furnace: 92G1UH030BE12*Cold climate designationAHRI reference: 217450649 | 18.05 | 8.50 | 28600 | 1.85 | EPA 4046206 → |
7AH1AV36PX-**Cold climate designationAHRI reference: 216013469 | 18.00 | 9.50 | 30000 | 1.80 | EPA 3801683 → |
7AH1AE42PX-**Cold climate designationAHRI reference: 216619077 | 18.00 | 9.00 | 30000 | 1.90 | EPA 3893065 → |
7AH2AE42PX-**Cold climate designationAHRI reference: 216705394 | 18.00 | 9.40 | 29000 | 1.90 | EPA 3893251 → |
7EH36CX-**+TDR+ furnace: 97G2UH090CV12*Cold climate designationAHRI reference: 216769731 | 18.00 | 9.00 | 28400 | 1.90 | EPA 3983727 → |
7E[C,U]36AX-**+TDR+ furnace: 80G1UH045AE12*Cold climate designationAHRI reference: 217189491 | 18.00 | 8.50 | 28400 | 1.85 | EPA 4007426 → |
7E[C,U]36AX-**+TDR+ furnace: 80G1UH045AE12L*Cold climate designationAHRI reference: 217189492 | 18.00 | 8.50 | 28400 | 1.85 | EPA 4007427 → |
7EH30BX-**+TDR+ furnace: 92G1UH030BE12*Cold climate designationAHRI reference: 217450658 | 18.00 | 8.50 | 28600 | 1.85 | EPA 4046199 → |
7EH30AX-**+TDR+ furnace: 80G1UH040AE12X*Cold climate designationAHRI reference: 217189506 | 17.95 | 9.00 | 28400 | 1.90 | EPA 4007280 → |
7EH30AX-**+TDR+ furnace: 80G1UH060AE12X*Cold climate designationAHRI reference: 217189507 | 17.95 | 9.00 | 28400 | 1.90 | EPA 4007281 → |
7EH30AX-**+TDR+ furnace: 80G1UH070AE12*Cold climate designationAHRI reference: 217189511 | 17.95 | 9.00 | 28200 | 1.90 | EPA 4007285 → |
7EH36BX-**+TDR+ furnace: 80G1UH070BE12L*Cold climate designationAHRI reference: 217189536 | 17.95 | 8.50 | 28400 | 1.85 | EPA 4007499 → |
7E[C,U]36AX-**+TDR+ furnace: 80G1UH040AE12X*Cold climate designationAHRI reference: 217189485 | 17.95 | 8.50 | 28400 | 1.85 | EPA 4007597 → |
7EH30BX-**+TDR+ furnace: 80G1UH070BE12*Cold climate designationAHRI reference: 217189514 | 17.95 | 8.50 | 28400 | 1.85 | EPA 4007706 → |
7EH30BX-**+TDR+ furnace: 80G1UH070BE12L*Cold climate designationAHRI reference: 217189515 | 17.95 | 8.50 | 28400 | 1.85 | EPA 4007707 → |
7EH36BX-**+TDR+ furnace: 80G1UH070BE12*Cold climate designationAHRI reference: 217189535 | 17.95 | 8.50 | 28400 | 1.85 | EPA 4007764 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →