Ducane / AIR-SOURCE HEAT PUMP

7HP19V60P-**A

7HP19V SERIES · 7HP19V Series · A7HP19V Series · source records, page 3

76 published source records · source checked Sep 21, 2026

SEER2 range16–18BTU/Wh
HSPF2 range7.8–9BTU/Wh
Cooling capacity46,000–48,000BTU/h

Each efficiency range summarizes published EPA records for 7HP19V60P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 76 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–1876 / 76
EER2 · BTU/Wh11–11.776 / 76
HSPF2 · BTU/Wh7.8–976 / 76
Cooling capacity · BTU/h46,000–48,00076 / 76
Heating capacity at 47°F / 8.3°C · BTU/h45,500–50,50076 / 76
Heating capacity at 17°F / −8.3°C · BTU/h28,000–32,60076 / 76
Heating capacity at 5°F / −15°C · BTU/h22,000–29,80076 / 76
COP at 5°F / −15°C1.8–2.0676 / 76
Equipment / loop typeHP - Split System76 / 76
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)76 / 76
Compressor stagingContinuously variable76 / 76
Connected capabilityNo76 / 76

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7E[C,U]50/60CX-**+TDR+ furnace: EFV16CCA*AHRI reference: 21751303017.507.80238001.86EPA 4469720
7ED48CX-**+TDR+ furnace: 97G2DF090CV20*AHRI reference: 21751303717.508.10248001.88EPA 4469721
7ED48CX-**+TDR+ furnace: EFV16CCA*AHRI reference: 21751303917.508.10246001.90EPA 4469722
7ED48CX-**+TDR+ furnace: 97G2DF110CV20*AHRI reference: 21751303817.508.10248001.88EPA 4469723
7EH51CX-**+TDR+ furnace: EFV16CCA*AHRI reference: 21751304717.508.10290001.90EPA 4469724
7EH51CX-**+TDR+ furnace: 80G2UH110CV20**AHRI reference: 21751340317.508.10290001.90EPA 4469812
7EH51CX-**+TDR+ furnace: 97G2UH090CV20**AHRI reference: 21751340417.508.00292001.90EPA 4469813
7EH51CX-**+TDR+ furnace: 80G1UH110CE20*AHRI reference: 21746514517.508.20290001.90EPA 4470163
7EH51CX-**+TDR+ furnace: 80G1UH110CE20L*AHRI reference: 21746514617.508.20290001.90EPA 4470167
7EH51CX-**+TDR+ furnace: 92G1UH110CE16*AHRI reference: 21746514817.508.20286001.90EPA 4470175
7EH51CX-**+TDR+ furnace: 97G2UH110CV20*AHRI reference: 21746515217.508.10290001.92EPA 4470229
7EH51CX-**+TDR+ furnace: EFV16CCP-**AHRI reference: 21867203417.508.10290001.90EPA 4673153
7ED48CX-**+TDR+ furnace: EFV16CCP-**AHRI reference: 21867203117.508.10246001.90EPA 4673154
7E[C,U]50/60CX-**+TDR+ furnace: EFV16CCP-**AHRI reference: 21867202817.507.80238001.86EPA 4673155
7E[C,U]49CX-**+TDR+ furnace: 97G1UH080CE16*AHRI reference: 21879188817.509.00244001.96EPA 4706657
7E[C,U]50/60CX-**+TDR+ furnace: 80G1UH090CE20*AHRI reference: 21722233417.008.20232001.88EPA 4012565
7E[C,U]50/60CX-**+TDR+ furnace: 97G2UH110CE20*AHRI reference: 21722234317.008.20234001.86EPA 4012571
7E[C,U]48CX-**+TDR+ furnace: 95G1UH080CE16X*AHRI reference: 21722234817.007.80220001.80EPA 4012575
7E[C,U]50/60CX-**+TDR+ furnace: 96G1UH110CE20*AHRI reference: 21722234117.008.20234001.86EPA 4012704
7ED50/60CX-**+TDR+ furnace: 96G1DF090CE16*AHRI reference: 21746515617.008.00290001.94EPA 4469523

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →