Ducane / AIR-SOURCE HEAT PUMP

7HP19V60P-**A

7HP19V SERIES · 7HP19V Series · A7HP19V Series

76 published source records · source checked Sep 21, 2026

SEER2 range16–18BTU/Wh
HSPF2 range7.8–9BTU/Wh
Cooling capacity46,000–48,000BTU/h

Each efficiency range summarizes published EPA records for 7HP19V60P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 76 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–1876 / 76
EER2 · BTU/Wh11–11.776 / 76
HSPF2 · BTU/Wh7.8–976 / 76
Cooling capacity · BTU/h46,000–48,00076 / 76
Heating capacity at 47°F / 8.3°C · BTU/h45,500–50,50076 / 76
Heating capacity at 17°F / −8.3°C · BTU/h28,000–32,60076 / 76
Heating capacity at 5°F / −15°C · BTU/h22,000–29,80076 / 76
COP at 5°F / −15°C1.8–2.0676 / 76
Equipment / loop typeHP - Split System76 / 76
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)76 / 76
Compressor stagingContinuously variable76 / 76
Connected capabilityNo76 / 76

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7AH2AE48PX-**AHRI reference: 21720242718.008.20234002.06EPA 4012220
7AH1AE48PX-**AHRI reference: 21720242918.007.80234002.06EPA 4012222
7E[C,U]50/60CX-**+TDR+ furnace: 80G2UH110CE16*AHRI reference: 21722233118.008.20234001.88EPA 4012561
7E[C,U]50/60CX-**+TDR+ furnace: 80G1UH110CE20*AHRI reference: 21722233518.008.20236001.88EPA 4012566
7E[C,U]50/60CX-**+TDR+ furnace: 80G1UH110CE20L*AHRI reference: 21722233618.008.20236001.88EPA 4012567
7E[C,U]48CX-**+TDR+ furnace: 80G2UH110CE16*AHRI reference: 21722234918.007.80220001.82EPA 4012576
7E[C,U]48CX-**+TDR+ furnace: 92G1UH090CE16*AHRI reference: 21722235018.007.80220001.80EPA 4012577
7E[C,U]48CX-**+TDR+ furnace: 92G1UH110CE16*AHRI reference: 21722235118.007.80220001.82EPA 4012578
7EH48CX-**+TDR+ furnace: 80G2UH110CE16*AHRI reference: 21722235318.007.80234001.80EPA 4012579
7E[C,U]48CX-**+TDR+ furnace: 96G1UH090CE16*AHRI reference: 21722235218.007.80220001.82EPA 4012580
7E[C,U]48CX-**+TDR+ furnace: 97G2UH090CE16*AHRI reference: 21722235418.007.80220001.82EPA 4012583
7E[C,U]48BX-**+TDR+ furnace: 80G2UH090BE16*AHRI reference: 21722235818.007.80222001.80EPA 4012585
7E[C,U]48BX-**+TDR+ furnace: 80G1UH090BE16*AHRI reference: 21722236018.007.80220001.82EPA 4012586
7E[C,U]48BX-**+TDR+ furnace: 80G1UH090BE16L*AHRI reference: 21722236118.007.80220001.82EPA 4012587
7E[C,U]50/60CX-**+TDR+ furnace: 92G1UH090CE16*AHRI reference: 21722233718.008.20234001.86EPA 4012702
7E[C,U]50/60CX-**+TDR+ furnace: 96G1UH090CE16*AHRI reference: 21722234018.008.20234001.86EPA 4012703
7E[C,U]48BX-**+TDR+ furnace: 80G2UH090BE16L*AHRI reference: 21722235918.007.80222001.80EPA 4012705
7ED50/60CX-**+TDR+ furnace: 80G1DF110CE20*AHRI reference: 21746515418.008.00288001.96EPA 4469515
7ED50/60CX-**+TDR+ furnace: 92G1DF090CE16*AHRI reference: 21746515518.008.00294001.92EPA 4469519
7E[C,U]50/60CX-**+TDR+ furnace: 80G2UH110CV20**AHRI reference: 21751339918.008.00236001.86EPA 4469808