Ducane / AIR-SOURCE HEAT PUMP

7HP19V36P-**A

7HP19V SERIES · 7HP19V Series · A7HP19V Series · source records, page 4

198 published source records · source checked Sep 21, 2026

SEER2 range15.2–20BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity21,600–35,800BTU/h

Each efficiency range summarizes published EPA records for 7HP19V36P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 198 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–20198 / 198
EER2 · BTU/Wh11–13.2198 / 198
HSPF2 · BTU/Wh7.8–8.5198 / 198
Cooling capacity · BTU/h21,600–35,800198 / 198
Heating capacity at 47°F / 8.3°C · BTU/h22,800–36,000198 / 198
Heating capacity at 17°F / −8.3°C · BTU/h13,900–23,000198 / 198
Heating capacity at 5°F / −15°C · BTU/h12,100–17,700198 / 198
COP at 5°F / −15°C1.48–2.2198 / 198
Equipment / loop typeHP - Split System198 / 198
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)198 / 198
Compressor stagingContinuously variable198 / 198
Connected capabilityNo198 / 198

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EH30BX-**+TDR+ furnace: 97G2UH070BV12*AHRI reference: 21751300718.508.20151001.90EPA 4469765 →
7E[C,U]36BX-**+TDR*+ furnace: 92G1UH070BE12*AHRI reference: 21746442818.508.20148001.92EPA 4469982 →
7E[C,U]36AX-**+TDR*+ furnace: 80G1UH040AE12X*AHRI reference: 21746440818.508.20149001.90EPA 4470009 →
7E[C,U]36AX-**+TDR*+ furnace: 80G1UH060AE12X*AHRI reference: 21746440418.508.20149001.90EPA 4470013 →
7E[C,U]36AX-**+TDR*+ furnace: 80G2UH070AE12*AHRI reference: 21746439618.508.20148001.92EPA 4470022 →
7E[C,U]36AX-**+TDR*+ furnace: 80G2UH070AE12L*AHRI reference: 21746439218.508.20148001.92EPA 4470027 →
7E[C,U]36AX-**+TDR*+ furnace: 80G1UH045AE12*AHRI reference: 21746438818.508.20149001.92EPA 4470032 →
7E[C,U]36AX-**+TDR*+ furnace: 80G1UH045AE12L*AHRI reference: 21746438418.508.20149001.92EPA 4470037 →
7E[C,U]30BX-**+TDR+ furnace: 80G1UH070BE12*AHRI reference: 21746518718.508.20138001.88EPA 4470264 →
7E[C,U]30BX-**+TDR+ furnace: 80G1UH070BE12L*AHRI reference: 21746518818.508.20138001.88EPA 4470268 →
7E[C,U]30AX-**+TDR+ furnace: 80G1UH070AE12L*AHRI reference: 21746522018.508.20138001.88EPA 4470354 →
7EH30AX-**+TDR+ furnace: 80G2UH070AE12*AHRI reference: 21746522318.507.80150001.52EPA 4470366 →
7EH30AX-**+TDR+ furnace: 80G2UH070AE12L*AHRI reference: 21746522418.507.80150001.52EPA 4470371 →
7E[C,U]24BX-**+TDR+ furnace: 97G1UH060BE12*AHRI reference: 21879188318.508.50166002.02EPA 4706662 →
7E[C,U]24AX-**+TDR+ furnace: 80G1UH070AE12*AHRI reference: 21746518018.008.50164002.02EPA 4469544 →
7E[C,U]24BX-**+TDR+ furnace: 96G1UH045BE12*AHRI reference: 21746516618.008.50167002.02EPA 4469578 →
7E[C,U]24BX-**+TDR+ furnace: 97G2UH045BE12*AHRI reference: 21746517218.008.50167002.02EPA 4469597 →
7E[C,U]24AX-**+TDR+ furnace: 80G1UH070AE12L*AHRI reference: 21746518118.008.50163002.02EPA 4469606 →
7E[C,U]30BX-**+TDR+ furnace: EFV08BCA*AHRI reference: 21751298018.008.00141001.84EPA 4469753 →
7E[C,U]36BX-**+TDR+ furnace: 80G2UH090BV16*AHRI reference: 21751298318.008.20150001.92EPA 4469757 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →