Ducane / AIR-SOURCE HEAT PUMP

7HP14F48P-**A

7HP14F Series

17 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.5BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity48,000BTU/h

Each efficiency range summarizes published EPA records for 7HP14F48P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 17 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.517 / 17
EER2 · BTU/Wh12.4–1317 / 17
HSPF2 · BTU/Wh7.8–8.217 / 17
Cooling capacity · BTU/h48,00017 / 17
Heating capacity at 47°F / 8.3°C · BTU/h46,000–48,00017 / 17
Heating capacity at 17°F / −8.3°C · BTU/h29,600–30,60017 / 17
Heating capacity at 5°F / −15°C · BTU/h23,400–24,60017 / 17
COP at 5°F / −15°C2.12–2.217 / 17
Equipment / loop typeHP - Split System17 / 17
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)17 / 17
Compressor stagingSingle stage17 / 17
Connected capabilityNo17 / 17

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7AH2AV48PXC**AHRI reference: 21574699415.508.20242002.20EPA 3653226 →
7AH2AV60PXC**AHRI reference: 21574699515.508.20234002.12EPA 3653227 →
7E[C,U]60CX-**+TDR+ furnace: 80G1UH090CE20*AHRI reference: 21574702715.208.00242002.14EPA 3653212 →
7E[C,U]60CX-**+TDR+ furnace: 80G1UH110CE20*AHRI reference: 21574702815.208.00240002.12EPA 3653213 →
7E[C,U]60CX-**+TDR+ furnace: 80G1UH110CE20L*AHRI reference: 21574702915.208.00240002.12EPA 3653214 →
7E[C,U]60CX-**+TDR+ furnace: 92G1UH090CE16*AHRI reference: 21574703015.208.00242002.14EPA 3653215 →
7E[C,U]60CX-**+TDR+ furnace: 92G1UH110CE16*AHRI reference: 21574703115.208.00238002.12EPA 3653216 →
7E[C,U]60CX-**+TDR+ furnace: 92G1UH110CE20*AHRI reference: 21574703215.208.00240002.12EPA 3653217 →
7E[C,U]49CX-**+TDR+ furnace: 80G2UH110CE16*AHRI reference: 21574699715.207.80240002.14EPA 3653228 →
7E[C,U]60CX-**+TDR+ furnace: 97G2UH090CE16*AHRI reference: 21574703715.208.00242002.14EPA 3653231 →
7E[C,U]49CX-**+TDR+ furnace: 92G1UH110CE16*AHRI reference: 21574700615.207.80240002.12EPA 3653243 →
7AH2AE48PX-**AHRI reference: 21574699215.208.20246002.20EPA 3653264 →
7E[C,U]60CX-**+TDR+ furnace: 80G2UH110CE16*AHRI reference: 21574702315.208.00238002.14EPA 3653265 →
7E[C,U]60CX-**+TDR+ furnace: 80G2UH110CE20*AHRI reference: 21574702415.208.10242002.14EPA 3653266 →
7E[C,U]60CX-**+TDR+ furnace: 80G2UH110CE20L*AHRI reference: 21574702515.208.10242002.14EPA 3653267 →
7E[C,U]60CX-**+TDR+ furnace: 96G1UH090CE16*AHRI reference: 21574703815.208.00242002.14EPA 3653305 →
7E[C,U]60CX-**+TDR+ furnace: 80G2UH110CV20*AHRI reference: 21677952415.208.00240002.12EPA 3992955 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →