Ducane / AIR-SOURCE HEAT PUMP

7HP14F42P-**A

7HP14F Series · source records, page 2

48 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.5BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity41,000–42,000BTU/h

Each efficiency range summarizes published EPA records for 7HP14F42P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 48 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.548 / 48
EER2 · BTU/Wh12.5–13.248 / 48
HSPF2 · BTU/Wh7.8–8.248 / 48
Cooling capacity · BTU/h41,000–42,00048 / 48
Heating capacity at 47°F / 8.3°C · BTU/h39,000–40,50048 / 48
Heating capacity at 17°F / −8.3°C · BTU/h24,600–25,80048 / 48
Heating capacity at 5°F / −15°C · BTU/h19,000–20,80048 / 48
COP at 5°F / −15°C2–2.1448 / 48
Equipment / loop typeHP - Split System48 / 48
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)48 / 48
Compressor stagingSingle stage48 / 48
Connected capabilityNo48 / 48

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EH42BX-**+TDR+ furnace: 80G1UH090BE16L*AHRI reference: 21574325915.507.80194002.04EPA 3652990
7E[C,U]49CX-**+TDR+ furnace: 80G1UH110CE20L*AHRI reference: 21574323515.507.80195002.06EPA 3653041
7E[C,U]49CX-**+TDR+ furnace: 92G1UH090CE12*AHRI reference: 21574323615.507.80194002.04EPA 3653042
7E[C,U]49CX-**+TDR+ furnace: 92G1UH110CE16*AHRI reference: 21574323815.507.80193002.06EPA 3653044
7E[C,U]49CX-**+TDR+ furnace: 92G1UH110CE20*AHRI reference: 21574323915.507.80196002.06EPA 3653045
7E[C,U]49CX-**+TDR+ furnace: 96G1UH110CE20*AHRI reference: 21574324115.507.80195002.06EPA 3653047
7E[C,U]49CX-**+TDR+ furnace: 97G2UH110CV20*AHRI reference: 21649870415.507.80196002.04EPA 3847429
7E[C,U]49CX-**+TDR+ furnace: EFV16CCA*AHRI reference: 21761600915.507.80196002.04EPA 4481505
7E[C,U]49CX-**+TDR+ furnace: EFV16CCP-**AHRI reference: 21867207815.507.80196002.04EPA 4673138
7E[C,U]48CX-**+TDR+ furnace: 92G1UH090CE12*AHRI reference: 21574322015.207.80204002.10EPA 3652942
7E[C,U]48CX-**+TDR+ furnace: 92G1UH110CE20*AHRI reference: 21574322315.207.80206002.10EPA 3652944
7AH1AV48PX-**AHRI reference: 21574320515.208.00196002.08EPA 3652953
7AH2AV42PXC**AHRI reference: 21574320815.208.10202002.14EPA 3652956
7AH2AV48PXC**AHRI reference: 21574320915.208.20204002.14EPA 3652957
7E[C,U]48CX-**+TDR+ furnace: 97G2UH090CE16*AHRI reference: 21574321515.207.80208002.10EPA 3652961
7E[C,U]48CX-**+TDR+ furnace: 97G2UH110CE20*AHRI reference: 21574321615.207.80206002.08EPA 3652962
7E[C,U]49CX-**+TDR+ furnace: 95G1UH100CE20X*AHRI reference: 21574322715.207.80197002.04EPA 3652975
7E[C,U]49CX-**+TDR+ furnace: 97G2UH090CE16*AHRI reference: 21574323115.207.80199002.06EPA 3652980
7E[C,U]49CX-**+TDR+ furnace: 92G1UH090CE16*AHRI reference: 21574323715.207.80200002.06EPA 3653043
7E[C,U]49CX-**+TDR+ furnace: 96G1UH090CE16*AHRI reference: 21574324015.207.80200002.06EPA 3653046

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →