Ducane / AIR-SOURCE HEAT PUMP

7HP14F24P-**A

7HP14F SERIES · 7HP14F Series · source records, page 4

118 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,800–24,000BTU/h

Each efficiency range summarizes published EPA records for 7HP14F24P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 118 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16118 / 118
EER2 · BTU/Wh12–13.8118 / 118
HSPF2 · BTU/Wh7.8–8.2118 / 118
Cooling capacity · BTU/h22,800–24,000118 / 118
Heating capacity at 47°F / 8.3°C · BTU/h20,400–23,000118 / 118
Heating capacity at 17°F / −8.3°C · BTU/h12,900–14,700118 / 118
Heating capacity at 5°F / −15°C · BTU/h10,500–11,600118 / 118
COP at 5°F / −15°C1.96–2.2118 / 118
Equipment / loop typeHP - Split System118 / 118
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)118 / 118
Compressor stagingSingle stage118 / 118
Connected capabilityNo118 / 118

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EH30BX-**+TDR+ furnace: 92G1UH045BE12*AHRI reference: 21571092615.208.00112002.06EPA 3646293 →
7E[C,U]24BX-**+TDR+ furnace: 92G1UH045BE12*AHRI reference: 21571084815.207.80110002.02EPA 3646326 →
7E[C,U]24BX-**+TDR+ furnace: 92G1UH070BE12*AHRI reference: 21571084915.207.80110002.04EPA 3646327 →
7E[C,U]24BX-**+TDR+ furnace: 96G1UH070BE12*AHRI reference: 21571085115.207.80110002.04EPA 3646335 →
7E[C,U]30AX-**+TDR+ furnace: 80G1UH040AE12X*AHRI reference: 21571085215.208.00115002.14EPA 3646336 →
7E[C,U]30AX-**+TDR+ furnace: 80G1UH060AE12X*AHRI reference: 21571085315.208.00115002.14EPA 3646337 →
7E[C,U]30AX-**+TDR+ furnace: 80G2UH070AE12*AHRI reference: 21571085515.208.00116002.14EPA 3646339 →
7E[C,U]30AX-**+TDR+ furnace: 80G2UH070AE12L*AHRI reference: 21571085615.208.00116002.14EPA 3646340 →
7AH2AE24PX-**AHRI reference: 21571082215.208.20112002.16EPA 3646355 →
7E[C,U]24AX-**+TDR+ furnace: 80G1UH040AE12X*AHRI reference: 21571082615.207.80110002.02EPA 3646368 →
7E[C,U]24AX-**+TDR+ furnace: 80G1UH060AE12X*AHRI reference: 21571082715.207.80110002.02EPA 3646369 →
7E[C,U]24AX-**+TDR+ furnace: 80G2UH070AE12*AHRI reference: 21571082915.207.80110002.02EPA 3646370 →
7E[C,U]30BX-**+TDR+ furnace: 92G1UH070BE12*AHRI reference: 21571087515.208.10115002.14EPA 3646379 →
7AH2AV24PXC**AHRI reference: 21571082415.208.20112002.16EPA 3646384 →
7E[C,U]30BX-**+TDR+ furnace: 80G1UH080BE16X*AHRI reference: 21571086115.208.00115002.12EPA 3646440 →
7EH24AX-**+TDR+ furnace: 80G1UH070AE12*AHRI reference: 21571088515.207.80107001.98EPA 3646479 →
7EH24AX-**+TDR+ furnace: 80G1UH070AE12L*AHRI reference: 21571088615.207.80107001.98EPA 3646480 →
7EH24BX-**+TDR+ furnace: 80G1UH080BE16X*AHRI reference: 21571088715.208.00108001.98EPA 3646481 →
7EH30AX-**+TDR+ furnace: 80G2UH070AE12*AHRI reference: 21571090715.208.00113002.04EPA 3646482 →
7EH30AX-**+TDR+ furnace: 80G2UH070AE12L*AHRI reference: 21571090815.208.00113002.04EPA 3646483 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →