Ducane / AIR-SOURCE HEAT PUMP

4HP18V60P

4HP18V SERIES

20 published source records · source checked Sep 21, 2026

SEER2 range16–17.1BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity46,000–46,500BTU/h

Each efficiency range summarizes published EPA records for 4HP18V60P. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 20 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–17.120 / 20
EER2 · BTU/Wh11–11.720 / 20
HSPF2 · BTU/Wh7.8–8.520 / 20
Cooling capacity · BTU/h46,000–46,50020 / 20
Heating capacity at 47°F / 8.3°C · BTU/h46,000–46,50020 / 20
Heating capacity at 17°F / −8.3°C · BTU/h30,400–36,00020 / 20
Heating capacity at 5°F / −15°C · BTU/h26,000–28,80020 / 20
COP at 5°F / −15°C1.8–2.120 / 20
Equipment / loop typeHP - Split System20 / 20
Refrigerant / source-reported GWPR-410A (GWP:2088)20 / 20
Compressor stagingContinuously variable20 / 20
Connected capabilityNo20 / 20

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EAH1P48C+TDR+TXV+ furnace: 97G2UH090CV20AHRI reference: 21410024017.107.80270001.80EPA 4011290
EAH1P48C+TDR+TXV+ furnace: 97G2UH110CV20AHRI reference: 21410024117.107.80268001.80EPA 4011291
7EH48CX-0*+TDR+ furnace: 97G2UH090CV20AHRI reference: 21473096317.107.80270001.80EPA 4011386
7EH48CX-0*+TDR+ furnace: 97G2UH110CV20AHRI reference: 21473096717.107.80268001.80EPA 4011387
EA(C,U)1P49C+TDR+TXV+ furnace: 97G2UH090CV20AHRI reference: 21410023616.507.80266001.90EPA 4011286
EA(C,U)1P49C+TDR+TXV+ furnace: 97G2UH110CV20AHRI reference: 21410023716.507.80262001.90EPA 4011287
EAC4X49C+TDR+ furnace: 97G2UH090CV20AHRI reference: 21410023816.507.80266001.90EPA 4011288
EAC4X49C+TDR+ furnace: 97G2UH110CV20AHRI reference: 21410023916.507.80262001.90EPA 4011289
EAD4X-50/60C+TDR+ furnace: 97G2DF110CV20AHRI reference: 21410023216.508.50288002.08EPA 4011345
7ED50/60CX-0*+TDR+ furnace: 97G2DF110CV20AHRI reference: 21473052316.508.50288002.08EPA 4011374
7EC49CX-0*+TDR+ furnace: 97G2UH090CV20AHRI reference: 21473087916.507.80266001.90EPA 4011383
7EC49CX-0*+TDR+ furnace: 97G2UH110CV20AHRI reference: 21473088416.507.80262001.90EPA 4011385
EAC4X49C+ furnace: 92G1UH110CE20AHRI reference: 20690513416.007.80260001.92EPA 2447556
EA(C,U)1P49C+H4TXV02+ furnace: 92G1UH110CE20AHRI reference: 20690510016.007.80260001.92EPA 2447647
7EC49CX-0*+TDR+ furnace: 92G1UH110CE20AHRI reference: 21473087016.007.80260001.92EPA 3493205
EA(C,U)1P49C+TDR+TXV+ furnace: 97G2UH110CE20AHRI reference: 21393429616.007.80262001.90EPA 4011333
EAC4X49C+TDR+ furnace: 97G2UH110CE20AHRI reference: 21393429816.007.80262001.90EPA 4011334
EAD4X-50/60C+TDR+ furnace: 97G2DF110CE20AHRI reference: 21393437116.008.50286002.10EPA 4011341
7ED50/60CX-0*+TDR+ furnace: 97G2DF110CE20AHRI reference: 21473051916.008.50286002.10EPA 4011370
7EC49CX-0*+TDR+ furnace: 97G2UH110CE20AHRI reference: 21473088216.007.80262001.90EPA 4011384

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →