Ducane / AIR-SOURCE HEAT PUMP

4HP18V36P

4HP18V SERIES · source records, page 6

192 published source records · source checked Sep 21, 2026

SEER2 range16–19BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,000–34,800BTU/h

Each efficiency range summarizes published EPA records for 4HP18V36P. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 192 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–19192 / 192
EER2 · BTU/Wh11–12.3192 / 192
HSPF2 · BTU/Wh7.8–8.5192 / 192
Cooling capacity · BTU/h22,000–34,800192 / 192
Heating capacity at 47°F / 8.3°C · BTU/h22,000–34,800192 / 192
Heating capacity at 17°F / −8.3°C · BTU/h14,900–24,800192 / 192
Heating capacity at 5°F / −15°C · BTU/h14,100–20,000192 / 192
COP at 5°F / −15°C1.78–2.18192 / 192
Equipment / loop typeHP - Split System192 / 192
Refrigerant / source-reported GWPR-410A (GWP:2088)192 / 192
Compressor stagingContinuously variable192 / 192
Connected capabilityNo192 / 192

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EAC4X24B+TDR+ furnace: 97G2UH070BE12AHRI reference: 21393413018.507.80156002.03EPA 4010700 →
EAH1P30B+TDR+TXV+ furnace: 97G2UH070BE12AHRI reference: 21393413518.508.50152002.11EPA 4010705 →
7EH30BX-0*+TDR+ furnace: 97G2UH070BE12AHRI reference: 21473080818.508.50152002.11EPA 4010748 →
7EH48BX-0*+TDR+ furnace: 97G2UH070BV12AHRI reference: 21473083018.508.50185002.10EPA 4010753 →
EAH1P36B+TDR+TXV+ furnace: 97G2UH070BE12AHRI reference: 21393639818.508.50167001.98EPA 4010820 →
E*1P23B+TDR+TXV+ furnace: 97G2UH030BE08AHRI reference: 21409187418.508.10143001.89EPA 4010842 →
EA(C,U)1P24B+TDR+TXV+ furnace: 97G2UH030BE08AHRI reference: 21409187518.508.10143001.88EPA 4010843 →
EAC4X24B+TDR+ furnace: 97G2UH030BE08AHRI reference: 21409187718.508.10143001.88EPA 4010845 →
EAH1P48B+TDR+TXV+ furnace: 97G2UH070BV12AHRI reference: 21410019118.508.50185002.10EPA 4010891 →
EAH1P30B+H4TXV01+ furnace: 92G1UH030BE12AHRI reference: 20690326818.008.10152001.99EPA 2447546 →
ED1P30/36B+H4TXV02+ furnace: 92G1DF070BE12AHRI reference: 20690302418.008.10181002.02EPA 2447557 →
ED1P30/36B+H4TXV02+ furnace: 96G1DF045BE12AHRI reference: 20690302718.008.10179002.04EPA 2447558 →
ED1P30/36B+H4TXV02+ furnace: 92G1DF045BE12AHRI reference: 20690302318.008.10181002.04EPA 2447651 →
BCE7E24MAHRI reference: 20690314618.008.50152002.10EPA 2447653 →
EA(C,U)1P24B+H4TXV01+ furnace: 96G1UH045BE12AHRI reference: 20690318818.007.80156001.93EPA 2447736 →
EA(C,U)1P24B+H4TXV01+ furnace: 96G1UH070BE12AHRI reference: 20690318918.007.80156001.94EPA 2447743 →
EAH1P30B+H4TXV01+ furnace: 96G1UH070BE12AHRI reference: 20690327618.008.50153002.03EPA 2447745 →
E*1P23B+H4TXV01+ furnace: 96G1UH030BE08AHRI reference: 20690316618.008.10141001.88EPA 2447811 →
E*1P23B+H4TXV01+ furnace: 96G1UH070BE12AHRI reference: 20690316818.008.10146001.90EPA 2447812 →
E*1P23B+H4TXV01+ furnace: 96G1UH045BE12AHRI reference: 20690316718.008.10146001.90EPA 2447813 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →