Ducane / AIR-SOURCE HEAT PUMP

4HP17L48P-**A

4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 5

150 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.6BTU/Wh
HSPF2 range8–8.5BTU/Wh
Cooling capacity46,000–48,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L48P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 150 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.6150 / 150
EER2 · BTU/Wh12.5–13150 / 150
HSPF2 · BTU/Wh8–8.5150 / 150
Cooling capacity · BTU/h46,000–48,000150 / 150
Heating capacity at 47°F / 8.3°C · BTU/h44,500–47,000150 / 150
Heating capacity at 17°F / −8.3°C · BTU/h30,000–31,600150 / 150
Heating capacity at 5°F / −15°C · BTU/h24,200–25,600150 / 150
COP at 5°F / −15°C2.16–2.38150 / 150
Equipment / loop typeHP - Split System150 / 150
Refrigerant / source-reported GWPR-410A (GWP:2088)150 / 150
Compressor stagingSingle stage150 / 150
Connected capabilityNo150 / 150

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EAC4X49C+TDR+ furnace: 96G1UH090CE16AHRI reference: 21032485215.208.10254002.24EPA 2455527
EA(C;U)1P48C+TDR+TXV+ furnace: 96G1UH110CE20AHRI reference: 21032477415.208.10242002.18EPA 2455563
EAC4X49C+TDR+ furnace: 80G1UH110CE20AHRI reference: 21032485015.208.10256002.26EPA 2458326
EAC4X50/60C+TDR+ furnace: 80G2UH110CE20LAHRI reference: 21032487415.208.10242002.18EPA 2459855
EAC4X50/60C+TDR+ furnace: 80G1UH090CE20AHRI reference: 21032487215.208.00242002.18EPA 2459869
EAC4X49C+TDR+ furnace: 92G1UH110CE16AHRI reference: 21032485115.208.10254002.22EPA 2460080
BCE5V48M*4XAHRI reference: 21032476615.208.30242002.28EPA 2460325
EAC4X49C+TDR+ furnace: 96G1UH110CE20AHRI reference: 21032484615.208.10254002.26EPA 2460331
EAC4X50/60C+TDR+ furnace: 80G2UH110CE20AHRI reference: 21032487315.208.10242002.18EPA 2460611
EAC4X48C+TDR+ furnace: 96G1UH110CE20AHRI reference: 21032483815.208.10242002.18EPA 2460849
EAC4X48C+TDR+ furnace: 80G2UH110CE16AHRI reference: 21032484115.208.10244002.20EPA 2460864
EA(C;U)1P49C+TDR+TXV+ furnace: 96G1UH110CE20AHRI reference: 21032478215.208.10254002.26EPA 2460879
EA(C;U)1P48C+TDR+TXV+ furnace: 92G1UH110CE16AHRI reference: 21032477615.208.10244002.18EPA 2460888
EAC4X48B+TDR+ furnace: 80G1UH090BE16AHRI reference: 21032483315.208.10242002.18EPA 2460895
EA(C;U)1P48C+TDR+TXV+ furnace: 80G2UH110CE16AHRI reference: 21032477715.208.10244002.20EPA 2460905
EAC4X60C+TDR+ furnace: 95G1UH100CE20XAHRI reference: 21032485915.208.10254002.38EPA 2461070
EA(C;U)1P60C+TDR+TXV+ furnace: 95G1UH100CE20XAHRI reference: 21032479515.208.10254002.38EPA 2461835
EAC4X60C+TDR+ furnace: 92G1UH090CE16AHRI reference: 21032486515.208.10252002.34EPA 2461854
EA(C;U)1P50/60C+TDR+TXV+ furnace: 80G2UH110CE20AHRI reference: 21032480915.208.10242002.18EPA 2461861
EA(C;U)1P48B+TDR+TXV+ furnace: 80G1UH090BE16AHRI reference: 21032476915.208.10242002.18EPA 2461869