Ducane / AIR-SOURCE HEAT PUMP

4HP17L48P-**A

4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 3

150 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.6BTU/Wh
HSPF2 range8–8.5BTU/Wh
Cooling capacity46,000–48,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L48P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 150 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.6150 / 150
EER2 · BTU/Wh12.5–13150 / 150
HSPF2 · BTU/Wh8–8.5150 / 150
Cooling capacity · BTU/h46,000–48,000150 / 150
Heating capacity at 47°F / 8.3°C · BTU/h44,500–47,000150 / 150
Heating capacity at 17°F / −8.3°C · BTU/h30,000–31,600150 / 150
Heating capacity at 5°F / −15°C · BTU/h24,200–25,600150 / 150
COP at 5°F / −15°C2.16–2.38150 / 150
Equipment / loop typeHP - Split System150 / 150
Refrigerant / source-reported GWPR-410A (GWP:2088)150 / 150
Compressor stagingSingle stage150 / 150
Connected capabilityNo150 / 150

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA(C;U)1P49C+TDR+TXV+ furnace: 80G2UH110CE20LAHRI reference: 21032478415.408.10254002.26EPA 2461116 →
EAC4X60C+TDR+ furnace: 92G1UH110CE20AHRI reference: 21032486415.408.30254002.32EPA 2461392 →
EA(C;U)1P60C+TDR+TXV+ furnace: 92G1UH110CE20AHRI reference: 21032480015.408.30254002.32EPA 2461422 →
BCE7E48M*4XAHRI reference: 21032476715.408.50244002.34EPA 2461611 →
EAC4X49C+TDR+ furnace: 80G2UH110CE20LAHRI reference: 21032484815.408.10254002.26EPA 2461630 →
EA(C;U)1P60C+TDR+TXV+ furnace: 92G1UH110CE16AHRI reference: 21032480215.408.10252002.36EPA 2461844 →
EAC4X49C+TDR+ furnace: 92G1UH110CE20AHRI reference: 21032484515.408.10250002.24EPA 2461860 →
EAC4X60C+TDR+ furnace: 92G1UH110CE16AHRI reference: 21032486615.408.10252002.36EPA 2461865 →
EAH1P51C*+TDR+TXV+ furnace: 80G2UH110CE20LAHRI reference: 21173721015.408.30254002.28EPA 2463286 →
EAH1P51C*+TDR+TXV+ furnace: 96G1UH110CE20AHRI reference: 21173729215.408.30254002.28EPA 2463696 →
EAH1P51C*+TDR+TXV+ furnace: 80G2UH110CE16AHRI reference: 21173719615.408.30256002.30EPA 2468418 →
EAH1P51C*+TDR+TXV+ furnace: 80G2UH110CE20AHRI reference: 21173720315.408.30254002.28EPA 2468871 →
EAH1P51C*+TDR+TXV+ furnace: 92G1UH110CE16AHRI reference: 21173727615.408.30256002.32EPA 2469330 →
7EH51CX-0*+TDR+ furnace: 80G2UH110CE20LAHRI reference: 21471090715.408.30254002.28EPA 3484982 →
7EH51CX-0*+TDR+ furnace: 80G2UH110CE16AHRI reference: 21471090515.408.30256002.30EPA 3485065 →
7EH51CX-0*+TDR+ furnace: 80G2UH110CE20AHRI reference: 21471090615.408.30254002.28EPA 3485066 →
7EC49CX-0*+TDR+ furnace: 80G2UH110CE16AHRI reference: 21471095715.408.10254002.26EPA 3485104 →
7EC49CX-0*+TDR+ furnace: 80G2UH110CE20AHRI reference: 21471095815.408.10254002.26EPA 3485109 →
7EC49CX-0*+TDR+ furnace: 80G2UH110CE20LAHRI reference: 21471095915.408.10254002.26EPA 3485112 →
7EH51CX-0*+TDR+ furnace: 92G1UH110CE16AHRI reference: 21471091615.408.30256002.32EPA 3485137 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →