Ducane / AIR-SOURCE HEAT PUMP

4HP17L48P-**A

4HP17L · 4HP17L SERIES · 4HP17L Series

150 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.6BTU/Wh
HSPF2 range8–8.5BTU/Wh
Cooling capacity46,000–48,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L48P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 150 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.6150 / 150
EER2 · BTU/Wh12.5–13150 / 150
HSPF2 · BTU/Wh8–8.5150 / 150
Cooling capacity · BTU/h46,000–48,000150 / 150
Heating capacity at 47°F / 8.3°C · BTU/h44,500–47,000150 / 150
Heating capacity at 17°F / −8.3°C · BTU/h30,000–31,600150 / 150
Heating capacity at 5°F / −15°C · BTU/h24,200–25,600150 / 150
COP at 5°F / −15°C2.16–2.38150 / 150
Equipment / loop typeHP - Split System150 / 150
Refrigerant / source-reported GWPR-410A (GWP:2088)150 / 150
Compressor stagingSingle stage150 / 150
Connected capabilityNo150 / 150

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EAC4X60C+TDR+ furnace: 80G1UH090CE20AHRI reference: 21032485715.608.10252002.38EPA 2455473
EAC4X48C+TDR+ furnace: 80G2UH110CE20AHRI reference: 21032483415.608.10242002.20EPA 2455535
EA(C;U)1P60C+TDR+TXV+ furnace: 80G2UH110CE20LAHRI reference: 21032479715.608.30252002.38EPA 2459846
EA(C;U)1P49C+TDR+TXV+ furnace: 80G1UH090CE20AHRI reference: 21032478015.608.10250002.26EPA 2460342
EA(C;U)1P60C+TDR+TXV+ furnace: 80G2UH110CE20AHRI reference: 21032479615.608.30252002.38EPA 2460587
EAC4X48C+TDR+ furnace: 80G2UH110CE20LAHRI reference: 21032483515.608.10242002.20EPA 2460822
EAC4X60C+TDR+ furnace: 80G2UH110CE20AHRI reference: 21032486015.608.30252002.38EPA 2460835
EAC4X60C+TDR+ furnace: 80G2UH110CE16AHRI reference: 21032486815.608.30252002.36EPA 2461071
EA(C;U)1P48C+TDR+TXV+ furnace: 80G2UH110CE20AHRI reference: 21032477015.608.10242002.20EPA 2461110
EA(C;U)1P60C+TDR+TXV+ furnace: 80G1UH090CE20AHRI reference: 21032479315.608.10252002.38EPA 2461836
EA(C;U)1P48C+TDR+TXV+ furnace: 80G2UH110CE20LAHRI reference: 21032477115.608.10242002.20EPA 2462085
EA(C;U)1P60C+TDR+TXV+ furnace: 80G2UH110CE16AHRI reference: 21032480415.608.30252002.36EPA 2462338
EAC4X60C+TDR+ furnace: 80G2UH110CE20LAHRI reference: 21032486115.608.30252002.38EPA 2462390
EAC4X49C+TDR+ furnace: 80G1UH090CE20AHRI reference: 21032484415.608.10250002.26EPA 2462406
EAH1P51C*+TDR+TXV+ furnace: 80G1UH090CE20AHRI reference: 21173725015.608.30252002.30EPA 2462831
7EH51CX-0*+TDR+ furnace: 80G1UH090CE20AHRI reference: 21471091215.608.30252002.30EPA 3485090
7EC60CX-0*+TDR+ furnace: 80G2UH110CE16AHRI reference: 21471099415.608.30252002.36EPA 3485210
7EC60CX-0*+TDR+ furnace: 80G2UH110CE20AHRI reference: 21471099515.608.30252002.38EPA 3485279
7EC60CX-0*+TDR+ furnace: 80G2UH110CE20LAHRI reference: 21471099615.608.30252002.38EPA 3485280
7EC49CX-0*+TDR+ furnace: 80G1UH090CE20AHRI reference: 21471096515.608.10250002.26EPA 3485335

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →