Ducane / AIR-SOURCE HEAT PUMP

4HP17L36P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 9

297 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.7BTU/Wh
Cooling capacity34,800–36,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L36P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 297 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8297 / 297
EER2 · BTU/Wh12.2–14297 / 297
HSPF2 · BTU/Wh7.8–8.7297 / 297
Cooling capacity · BTU/h34,800–36,000297 / 297
Heating capacity at 47°F / 8.3°C · BTU/h32,400–36,000297 / 297
Heating capacity at 17°F / −8.3°C · BTU/h21,400–23,800297 / 297
Heating capacity at 5°F / −15°C · BTU/h16,800–19,200297 / 297
COP at 5°F / −15°C2.06–2.36297 / 297
Equipment / loop typeHP - Split System297 / 297
Refrigerant / source-reported GWPR-410A (GWP:2088)297 / 297
Compressor stagingSingle stage297 / 297
Connected capabilityNo297 / 297

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EAH1P48B*+TDR+TXV+ furnace: 80G1UH070BE12AHRI reference: 21173639316.008.00173002.18EPA 2463264
EAH1P48B*+TDR+TXV+ furnace: 92G1UH070BE12AHRI reference: 21173645416.007.80172002.20EPA 2463675
BCE7S42M*4XAHRI reference: 21185560316.008.30180002.34EPA 2464143
BCE7E42M*4XAHRI reference: 21185561016.008.30181002.36EPA 2464539
EAH1P51C*+TDR+TXV+ furnace: 80G1UH100CE20XAHRI reference: 21173653416.008.00176002.18EPA 2464919
EAH1P51C*+TDR+TXV+ furnace: 95G1UH080CE16XAHRI reference: 21173654816.007.80176002.18EPA 2466631
EAH1P51C*+TDR+TXV+ furnace: 80G2UH110CV20AHRI reference: 21173682216.008.00179002.20EPA 2468432
EAD4X-30/36C+TDR+ furnace: 96G1DF090CE16AHRI reference: 21326506116.008.00187002.16EPA 2839677
7EC50/60CX-0*+TDR+ furnace: 95G1UH100CE20XAHRI reference: 21471071916.007.80172002.12EPA 3484767
7EC50/60CX-0*+TDR+ furnace: 97G2UH090CE16AHRI reference: 21471072316.007.80171002.12EPA 3484800
7EC50/60CX-0*+TDR+ furnace: 97G2UH090CV12AHRI reference: 21471072416.007.80173002.12EPA 3484801
7EC50/60CX-0*+TDR+ furnace: 97G2UH110CE20AHRI reference: 21471072616.007.80172002.10EPA 3484803
7ED30/36CX-0*+TDR+ furnace: 96G1DF090CE16AHRI reference: 21471065216.008.00187002.16EPA 3484860
7EC36BX-0*+TDR+ furnace: 92G1UH070BE12AHRI reference: 21471069116.007.80171002.14EPA 3484881
7EH42CX-0*+TDR+ furnace: 97G2UH090CV20AHRI reference: 21471058216.008.10184002.18EPA 3484883
7EH51CX-0*+TDR+ furnace: 80G2UH110CV20AHRI reference: 21471063716.008.00179002.20EPA 3484992
7EH42BX-0*+TDR+ furnace: 92G1UH070BE12AHRI reference: 21471056916.008.10183002.22EPA 3485021
7EC36BX-0*+TDR+ furnace: 97G2UH045BE12AHRI reference: 21471068116.007.80171002.14EPA 3485027
7EH42BX-0*+TDR+ furnace: 80G1UH070BE12AHRI reference: 21471056316.008.10184002.24EPA 3485043
7EH42BX-0*+TDR+ furnace: 80G1UH070BE12LAHRI reference: 21471056416.008.10184002.24EPA 3485044

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.