Ducane / AIR-SOURCE HEAT PUMP

4HP17L30P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 13

249 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,600BTU/h

Each efficiency range summarizes published EPA records for 4HP17L30P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 249 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2249 / 249
EER2 · BTU/Wh12.2–13.5249 / 249
HSPF2 · BTU/Wh7.8–8.6249 / 249
Cooling capacity · BTU/h28,200–30,600249 / 249
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000249 / 249
Heating capacity at 17°F / −8.3°C · BTU/h17,400–19,600249 / 249
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400249 / 249
COP at 5°F / −15°C1.96–2.36249 / 249
Equipment / loop typeHP - Split System249 / 249
Refrigerant / source-reported GWPR-410A (GWP:2088)249 / 249
Compressor stagingSingle stage249 / 249
Connected capabilityNo249 / 249

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7AH1AC36PX-0*AHRI reference: 21486577815.408.10136002.14EPA 3553839
EA(C;U)1P30B+TDR+TXV+ furnace: 80G1UH080BE16XAHRI reference: 21032507715.208.00147002.16EPA 2461149
EAC4X30B+TDR+ furnace: 80G1UH080BE16XAHRI reference: 21032524615.208.00147002.16EPA 2461626
EAH1P30A*+TDR+TXV+ furnace: 80G1UH060AE12XAHRI reference: 21173579115.207.80141001.96EPA 2468391
EAH1P30A*+TDR+TXV+ furnace: 80G1UH040AE12XAHRI reference: 21173577915.207.80141001.96EPA 2468402
7EH30AX-0*+TDR+ furnace: 80G1UH040AE12XAHRI reference: 21471042515.207.80141001.96EPA 3485007
7EH30AX-0*+TDR+ furnace: 80G1UH060AE12XAHRI reference: 21471042615.207.80141001.96EPA 3485008
7EC30BX-0*+TDR+ furnace: 80G1UH080BE16XAHRI reference: 21471049915.208.00147002.16EPA 3485123
7EH36CX-0*+TDR+ furnace: 97G2UH110CV20AHRI reference: 21471046715.208.50152002.22EPA 3485194

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →