Ducane / AIR-SOURCE HEAT PUMP

4HP17L30P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series

249 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,600BTU/h

Each efficiency range summarizes published EPA records for 4HP17L30P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 249 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2249 / 249
EER2 · BTU/Wh12.2–13.5249 / 249
HSPF2 · BTU/Wh7.8–8.6249 / 249
Cooling capacity · BTU/h28,200–30,600249 / 249
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000249 / 249
Heating capacity at 17°F / −8.3°C · BTU/h17,400–19,600249 / 249
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400249 / 249
COP at 5°F / −15°C1.96–2.36249 / 249
Equipment / loop typeHP - Split System249 / 249
Refrigerant / source-reported GWPR-410A (GWP:2088)249 / 249
Compressor stagingSingle stage249 / 249
Connected capabilityNo249 / 249

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA(C;U)1P36B+TDR+TXV+ furnace: 80G2UH090BE16AHRI reference: 21032511916.208.10141002.28EPA 2455540
EA(C;U)1P36B+TDR+TXV+ furnace: 80G1UH090BE16AHRI reference: 21032511716.208.10141002.26EPA 2455596
EAC4X36B+TDR+ furnace: 80G1UH090BE16AHRI reference: 21032529416.208.10141002.26EPA 2455712
EAC4X36B+TDR+ furnace: 80G2UH090BE16LAHRI reference: 21032529816.208.10141002.28EPA 2460579
EA(C;U)1P36B+TDR+TXV+ furnace: 80G2UH090BE16LAHRI reference: 21032512116.208.10141002.28EPA 2461874
EA(C;U)1P36B+TDR+TXV+ furnace: 80G2UH090BE12AHRI reference: 21032513716.208.10143002.30EPA 2462327
EAC4X36B+TDR+ furnace: 80G2UH090BE16AHRI reference: 21032529616.208.10141002.28EPA 2462396
EAC4X36B+TDR+ furnace: 80G2UH090BE12AHRI reference: 21032531416.208.10143002.30EPA 2462408
EAH1P36C*+TDR+TXV+ furnace: 80G1UH100CE20XAHRI reference: 21173591016.208.00138002.10EPA 2466204
EAD4X-42B+TDR+ furnace: 80G1DF090BE16AHRI reference: 21326504616.208.60148002.34EPA 2839609
7EH30BX-0*+TDR+ furnace: 80G2UH090BE12AHRI reference: 21471043916.208.00135002.12EPA 3485101
7EH30BX-0*+TDR+ furnace: 80G2UH090BE16AHRI reference: 21471044016.207.80134002.12EPA 3485102
7EH30BX-0*+TDR+ furnace: 80G2UH090BE16LAHRI reference: 21471044116.207.80134002.12EPA 3485103
7EH30BX-0*+TDR+ furnace: 80G1UH070BE12AHRI reference: 21471044616.207.80134002.12EPA 3485110
7EH30BX-0*+TDR+ furnace: 80G1UH070BE12LAHRI reference: 21471044716.207.80134002.12EPA 3485159
7EH30BX-0*+TDR+ furnace: 80G1UH090BE16AHRI reference: 21471044816.207.80134002.10EPA 3485160
7EH30BX-0*+TDR+ furnace: 80G1UH090BE16LAHRI reference: 21471044916.207.80134002.10EPA 3485224
7EC36BX-0*+TDR+ furnace: 80G2UH090BE12AHRI reference: 21471053516.208.10143002.30EPA 3485305
7EC36BX-0*+TDR+ furnace: 80G2UH090BE16AHRI reference: 21471053616.208.10141002.28EPA 3485306
7EC36BX-0*+TDR+ furnace: 80G2UH090BE16LAHRI reference: 21471053716.208.10141002.28EPA 3485307

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.