Ducane / AIR-SOURCE HEAT PUMP

4HP17L24P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 8

257 published source records · source checked Sep 21, 2026

SEER2 range15.4–17BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,400–24,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L24P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 257 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.4–17257 / 257
EER2 · BTU/Wh12.5–14257 / 257
HSPF2 · BTU/Wh7.8–8.2257 / 257
Cooling capacity · BTU/h22,400–24,000257 / 257
Heating capacity at 47°F / 8.3°C · BTU/h21,000–22,600257 / 257
Heating capacity at 17°F / −8.3°C · BTU/h13,400–14,700257 / 257
Heating capacity at 5°F / −15°C · BTU/h10,200–11,500257 / 257
COP at 5°F / −15°C2–2.18257 / 257
Equipment / loop typeHP - Split System257 / 257
Refrigerant / source-reported GWPR-410A (GWP:2088)257 / 257
Compressor stagingSingle stage257 / 257
Connected capabilityNo257 / 257

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EAH1P30A*+TDR+TXV+ furnace: 80G2UH070AE12AHRI reference: 21173505016.008.10108002.12EPA 2471711
EAH1P30A*+TDR+TXV+ furnace: 80G1UH060AE12XAHRI reference: 21173503216.008.10105002.10EPA 2471817
EAC4X24B+TDR+ furnace: 92G1UH070BE12AHRI reference: 21032556516.007.80106002.06EPA 2471846
EAC4X24B+TDR+ furnace: 80G2UH090BV16AHRI reference: 21032558116.007.80104002.04EPA 2471855
EAH1P24A*+TDR+TXV+ furnace: 80G2UH070AE12AHRI reference: 21173494216.007.80105002.04EPA 2471935
EAC4X24A+TDR+ furnace: 80G2UH070AE12LAHRI reference: 21032555816.007.80106002.02EPA 2471957
EAC4X24B+TDR+ furnace: 80G2UH090BE12AHRI reference: 21032557616.007.80106002.02EPA 2471958
EAC4X30B+TDR+ furnace: 80G2UH090BE12AHRI reference: 21032563016.007.80106002.00EPA 2472067
EAC4X24A+TDR+ furnace: 80G1UH040AE12XAHRI reference: 21032555916.007.80106002.02EPA 2472072
EAC4X24A+TDR+ furnace: 80G1UH060AE12XAHRI reference: 21032556016.007.80106002.02EPA 2472172
EAC4X30B+TDR+ furnace: 80G2UH090BV16AHRI reference: 21032563516.007.80104002.00EPA 2472181
EAH1P24A*+TDR+TXV+ furnace: 80G2UH070AE12LAHRI reference: 21173495116.007.80105002.04EPA 2472482
EAD4X-30/36B+TDR+ furnace: 80G1DF070BE12AHRI reference: 21326503216.008.10112002.10EPA 2648890
EAD4X-30/36B+TDR+ furnace: 80G2DF090BE16AHRI reference: 21326502816.008.20112002.08EPA 2648931
EAH1P30B*+TDR+TXV+ furnace: 96G1UH045BE12AHRI reference: 21173530016.007.80108002.04EPA 2837365
7EH24AX-0*+TDR+ furnace: 80G2UH070AE12AHRI reference: 21471030316.007.80105002.04EPA 3484745
7EH24AX-0*+TDR+ furnace: 80G2UH070AE12LAHRI reference: 21471030416.007.80105002.04EPA 3484748
7EC24BX-0*+TDR+ furnace: 97G2UH045BV12AHRI reference: 21471037816.007.80104002.02EPA 3484750
7EH30AX-0*+TDR+ furnace: 80G2UH070AE12AHRI reference: 21471031416.008.10108002.12EPA 3484775
7EC24AX-0*+TDR+ furnace: 80G1UH040AE12XAHRI reference: 21471036016.007.80106002.02EPA 3484808

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →