Ducane / AIR-SOURCE HEAT PUMP

4HP17L24P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 5

257 published source records · source checked Sep 21, 2026

SEER2 range15.4–17BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,400–24,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L24P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 257 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.4–17257 / 257
EER2 · BTU/Wh12.5–14257 / 257
HSPF2 · BTU/Wh7.8–8.2257 / 257
Cooling capacity · BTU/h22,400–24,000257 / 257
Heating capacity at 47°F / 8.3°C · BTU/h21,000–22,600257 / 257
Heating capacity at 17°F / −8.3°C · BTU/h13,400–14,700257 / 257
Heating capacity at 5°F / −15°C · BTU/h10,200–11,500257 / 257
COP at 5°F / −15°C2–2.18257 / 257
Equipment / loop typeHP - Split System257 / 257
Refrigerant / source-reported GWPR-410A (GWP:2088)257 / 257
Compressor stagingSingle stage257 / 257
Connected capabilityNo257 / 257

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EC30AX-0*+TDR+ furnace: 80G2UH045AE12AHRI reference: 21471039516.407.80102002.06EPA 3495262 →
7EC30BX-0*+TDR+ furnace: 80G1UH070BE12AHRI reference: 21471041416.407.80104002.06EPA 3495283 →
EAH1P30B*+TDR+TXV+ furnace: 80G1UH080BE16XAHRI reference: 21173511416.407.80106002.02EPA 3990312 →
EA(C;U)1P30B+TDR+TXV+ furnace: 92G1UH070BE12AHRI reference: 21032542016.207.80106002.04EPA 2471386 →
EA(C;U)1P30B+TDR+TXV+ furnace: 92G1UH030BE12AHRI reference: 21032541716.207.80102002.00EPA 2471413 →
EA(C;U)1P30A+TDR+TXV+ furnace: 80G1UH045AE12AHRI reference: 21032539616.207.80102002.02EPA 2471416 →
EA(C;U)1P30A+TDR+TXV+ furnace: 80G1UH070AE12AHRI reference: 21032539816.207.80104002.04EPA 2471424 →
EA(C;U)1P30A+TDR+TXV+ furnace: 80G1UH070AE12LAHRI reference: 21032540016.207.80104002.04EPA 2471450 →
EA(C;U)1P24A+TDR+TXV+ furnace: 80G2UH070AV12AHRI reference: 21032535616.207.80104002.04EPA 2471457 →
EA(C;U)1P24A+TDR+TXV+ furnace: 80G1UH070AE12AHRI reference: 21032533916.207.80104002.02EPA 2471464 →
BCE7E24M*4XAHRI reference: 21032533316.208.10104002.12EPA 2471560 →
EA(C;U)1P24A+TDR+TXV+ furnace: 80G1UH070AE12LAHRI reference: 21032534116.207.80104002.02EPA 2471566 →
EAC4X30B+TDR+ furnace: 92G1UH070BE12AHRI reference: 21032561816.207.80106002.04EPA 2471629 →
EAC4X30A+TDR+ furnace: 80G1UH070AE12LAHRI reference: 21032559916.207.80104002.04EPA 2471638 →
EAH1P24A*+TDR+TXV+ furnace: 80G2UH070AV12AHRI reference: 21173500116.207.80106002.08EPA 2471709 →
EAC4X30B+TDR+ furnace: 92G1UH030BE12AHRI reference: 21032561416.207.80102002.00EPA 2471726 →
EAC4X30A+TDR+ furnace: 80G1UH070AE12AHRI reference: 21032559716.207.80104002.04EPA 2471844 →
EAC4X24A+TDR+ furnace: 80G1UH070AE12LAHRI reference: 21032555216.207.80104002.02EPA 2471848 →
EAC4X30A+TDR+ furnace: 80G1UH045AE12AHRI reference: 21032559516.207.80102002.02EPA 2471849 →
EAH1P24A*+TDR+TXV+ furnace: 80G1UH045AE12AHRI reference: 21173496116.207.80102002.04EPA 2471933 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.