4HP17L24P-**A
4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 10
257 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 4HP17L24P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 257 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.4–17 | 257 / 257 |
| EER2 · BTU/Wh | 12.5–14 | 257 / 257 |
| HSPF2 · BTU/Wh | 7.8–8.2 | 257 / 257 |
| Cooling capacity · BTU/h | 22,400–24,000 | 257 / 257 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 21,000–22,600 | 257 / 257 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 13,400–14,700 | 257 / 257 |
| Heating capacity at 5°F / −15°C · BTU/h | 10,200–11,500 | 257 / 257 |
| COP at 5°F / −15°C | 2–2.18 | 257 / 257 |
| Equipment / loop type | HP - Split System | 257 / 257 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 257 / 257 |
| Compressor staging | Single stage | 257 / 257 |
| Connected capability | No | 257 / 257 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
7EC30AX-0*+TDR+ furnace: 80G1UH060AE12XAHRI reference: 214710394 | 16.00 | 7.80 | 10600 | 2.04 | EPA 3495259 → |
7AH1AE24PX-0*AHRI reference: 214865814 | 16.00 | 7.80 | 10400 | 2.08 | EPA 3553734 → |
7AH1AE30PX-0*AHRI reference: 214865816 | 16.00 | 8.10 | 10800 | 2.06 | EPA 3553735 → |
7AH1AV30PX-0*AHRI reference: 214865798 | 16.00 | 8.10 | 10400 | 2.06 | EPA 3553912 → |
7AH2AE30PX-0*AHRI reference: 214865800 | 16.00 | 8.20 | 10800 | 2.16 | EPA 3553913 → |
EA(C;U)1P24A+TDR+TXV+ furnace: 80G1UH060AE12XAHRI reference: 210325354 | 16.00 | 7.80 | 10600 | 2.02 | EPA 3984192 → |
EAC4X24A+TDR+ furnace: 80G2UH070AE12AHRI reference: 210325557 | 16.00 | 7.80 | 10600 | 2.02 | EPA 3984990 → |
EAC4X30A+TDR+ furnace: 80G1UH060AE12XAHRI reference: 210325609 | 16.00 | 7.80 | 10600 | 2.04 | EPA 3985007 → |
EAH1P30B*+TDR+TXV+ furnace: 95G1UH060BE12XAHRI reference: 211735130 | 16.00 | 7.80 | 10800 | 2.02 | EPA 3990314 → |
EAH1P30B*+TDR+TXV+ furnace: 96G1UH070BE12AHRI reference: 211735316 | 16.00 | 7.80 | 10800 | 2.04 | EPA 3990365 → |
EA(C;U)1P30B+TDR+TXV+ furnace: 92G1UH045BE12AHRI reference: 210325418 | 15.80 | 7.80 | 10600 | 2.00 | EPA 2471385 → |
EA(C;U)1P30A+TDR+TXV+ furnace: 80G2UH070AE12AHRI reference: 210325404 | 15.80 | 7.80 | 10600 | 2.04 | EPA 2471389 → |
EA(C;U)1P30A+TDR+TXV+ furnace: 80G2UH070AE12LAHRI reference: 210325406 | 15.80 | 7.80 | 10600 | 2.04 | EPA 2471395 → |
EA(C;U)1P24B+TDR+TXV+ furnace: 80G1UH080BE16XAHRI reference: 210325390 | 15.80 | 7.80 | 10600 | 2.02 | EPA 2471452 → |
EA(C;U)1P24B+TDR+TXV+ furnace: 92G1UH045BE12AHRI reference: 210325360 | 15.80 | 7.80 | 10600 | 2.00 | EPA 2471547 → |
EAC4X30A+TDR+ furnace: 80G2UH070AE12LAHRI reference: 210325605 | 15.80 | 7.80 | 10600 | 2.04 | EPA 2471728 → |
EAC4X24B+TDR+ furnace: 80G1UH080BE16XAHRI reference: 210325589 | 15.80 | 7.80 | 10600 | 2.02 | EPA 2471842 → |
EAC4X30A+TDR+ furnace: 80G2UH070AE12AHRI reference: 210325603 | 15.80 | 7.80 | 10600 | 2.04 | EPA 2471962 → |
EAC4X24B+TDR+ furnace: 92G1UH045BE12AHRI reference: 210325564 | 15.80 | 7.80 | 10600 | 2.00 | EPA 2471963 → |
EAH1P24A*+TDR+TXV+ furnace: 80G1UH040AE12XAHRI reference: 211734912 | 15.80 | 7.80 | 10600 | 2.04 | EPA 2472053 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.