Ducane / AIR-SOURCE HEAT PUMP

4HP17L18P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 9

256 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity18,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L18P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 256 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8256 / 256
EER2 · BTU/Wh12.2–14256 / 256
HSPF2 · BTU/Wh7.8–8.5256 / 256
Cooling capacity · BTU/h18,000256 / 256
Heating capacity at 47°F / 8.3°C · BTU/h16,000–18,000256 / 256
Heating capacity at 17°F / −8.3°C · BTU/h10,200–12,100256 / 256
Heating capacity at 5°F / −15°C · BTU/h7,500–9,700256 / 256
COP at 5°F / −15°C1.9–2.16256 / 256
Equipment / loop typeHP - Split System256 / 256
Refrigerant / source-reported GWPR-410A (GWP:2088)256 / 256
Compressor stagingSingle stage256 / 256
Connected capabilityNo256 / 256

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EAC4X24A+TDR+ furnace: 80G2UH045AE12AHRI reference: 21032578716.008.1084002.06EPA 2460324
EA(C;U)1P24B+TDR+TXV+ furnace: 95G1UH040BE12XAHRI reference: 21032567616.008.0082002.06EPA 2461126
EA(C;U)1P30A+TDR+TXV+ furnace: 80G1UH040AE12XAHRI reference: 21032569416.007.8075001.92EPA 2461423
EAC4X24B+TDR+ furnace: 95G1UH040BE12XAHRI reference: 21032579116.008.0082002.06EPA 2461642
EA(C;U)1P24B+TDR+TXV+ furnace: 92G1UH045BE12AHRI reference: 21032568016.008.0082002.06EPA 2461658
EA(C;U)1P24B+TDR+TXV+ furnace: 96G1UH070BE12AHRI reference: 21032568216.008.0082002.08EPA 2461880
EA(C;U)1P24A+TDR+TXV+ furnace: 80G2UH045AE12AHRI reference: 21032566916.008.1084002.06EPA 2461885
EA(C;U)1P24B+TDR+TXV+ furnace: 96G1UH045BE12AHRI reference: 21032567416.008.0082002.04EPA 2461892
EAC4X24A+TDR+ furnace: 80G2UH070AV12AHRI reference: 21032578816.008.1085002.06EPA 2462354
EAH1P24A*+TDR+TXV+ furnace: 80G1UH060AE12XAHRI reference: 21173429716.007.8081002.00EPA 2463231
EAH1P24A*+TDR+TXV+ furnace: 80G2UH070AV12AHRI reference: 21173438516.008.1087002.04EPA 2463652
EAH1P24B*+TDR+TXV+ furnace: 92G1UH030BE12AHRI reference: 21173454516.008.1084002.08EPA 2464077
EAH1P24B*+TDR+TXV+ furnace: 80G2UH090BV16AHRI reference: 21173462916.008.1087002.08EPA 2464464
EAH1P24A*+TDR+TXV+ furnace: 80G1UH040AE12XAHRI reference: 21173428716.007.8081002.00EPA 2464867
EAH1P24B*+TDR+TXV+ furnace: 96G1UH045BE12AHRI reference: 21173459916.008.1082002.06EPA 2465726
EAH1P30B*+TDR+TXV+ furnace: 96G1UH030BE08AHRI reference: 21173479216.007.8078001.98EPA 2465735
EAH1P24A*+TDR+TXV+ furnace: 80G2UH045AE12AHRI reference: 21173430616.008.1082002.02EPA 2467030
EAH1P24B*+TDR+TXV+ furnace: 95G1UH040BE12XAHRI reference: 21173441516.008.1082002.06EPA 2467498
EAH1P24B*+TDR+TXV+ furnace: 96G1UH070BE12AHRI reference: 21173461216.008.1082002.06EPA 2467940
EAD4X-30/36C+TDR+ furnace: 96G1DF090CE16AHRI reference: 21326502716.008.4093002.06EPA 2839631

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →