Day & Night / AIR-SOURCE HEAT PUMP

R5H5S24*K*AAA*

15 SEER2 HP · source records, page 3

187 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–24,400BTU/h

Each efficiency range summarizes published EPA records for R5H5S24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 187 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5187 / 187
EER2 · BTU/Wh11.7–13187 / 187
HSPF2 · BTU/Wh7.8–8.5187 / 187
Cooling capacity · BTU/h22,200–24,400187 / 187
Heating capacity at 47°F / 8.3°C · BTU/h21,600–24,000187 / 187
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,200187 / 187
Heating capacity at 5°F / −15°C · BTU/h10,800–11,900187 / 187
COP at 5°F / −15°C1.96–2.26187 / 187
Equipment / loop typeHP - Split System187 / 187
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)187 / 187
Compressor stagingSingle stage187 / 187
Connected capabilityNo187 / 187

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X25M17A*+ furnace: *96CTN0801714B*AHRI reference: 21419838215.507.80113002.10EPA 3405526 →
EA*5X25M17A*+ furnace: *96CTN0601714B*AHRI reference: 21419835515.507.80114002.10EPA 3405560 →
EA*5X25M17A*+ furnace: *80CTL0451712B*AHRI reference: 21419755415.507.80115002.10EPA 3405627 →
EA*5X25M17A*+ furnace: *80CTL0701716B*AHRI reference: 21419758115.507.80114002.10EPA 3405655 →
EA*5X25M17A*+ furnace: *95CSU0601716B*AHRI reference: 21419774215.507.80113002.10EPA 3405835 →
EA*5X25M17A*+ furnace: *97CMN0601714B*AHRI reference: 21419782315.507.80115002.10EPA 3405960 →
EA*5X25M17A*+ furnace: *97CMN0801714B*AHRI reference: 21419785015.507.80115002.12EPA 3405990 →
EVM5X32M17A*+ furnace: *96VSN0801716B*AHRI reference: 21420471315.507.80113001.98EPA 3406307 →
EVD5X31M17A*+ furnace: *95MSU0601716A*AHRI reference: 21420561315.507.80113001.98EPA 3406332 →
EA*5X37M21A*+ furnace: *80CTL1102120B*AHRI reference: 21420196415.507.80116002.14EPA 3406432 →
EA*5X37M21A*+ furnace: *97CMN0601714B*AHRI reference: 21420231315.507.80117002.12EPA 3406444 →
EA*5X37M21A*+ furnace: *95MSU0802120A*AHRI reference: 21420285015.507.80116002.14EPA 3406561 →
EVD5X38M17A*+ furnace: *96VTN0801716B*AHRI reference: 21420779115.507.80113001.98EPA 3406580 →
EA*5X37M17A*+ furnace: *80CSU0401712A*AHRI reference: 21419945115.507.80112002.08EPA 3406662 →
EA*5X37M21A*+ furnace: *80VTL0902120B*AHRI reference: 21420207215.507.80116002.14EPA 3406791 →
EA*5X37M21A*+ furnace: *80CSU1002120A*AHRI reference: 21420135615.507.80115002.12EPA 3406830 →
EA*5X37M21A*+ furnace: *96CTN0601714B*AHRI reference: 21420295815.507.80116002.12EPA 3406905 →
EA*5X37M21A*+ furnace: *80CSU0601716A*AHRI reference: 21420132915.507.80113002.12EPA 3406927 →
EA*5X37M21A*+ furnace: *95CSU0601716B*AHRI reference: 21420215115.507.80116002.14EPA 3406970 →
EA*5X37M21A*+ furnace: *95CSU0802120B*AHRI reference: 21420217815.507.80116002.14EPA 3406997 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →