Q5H9V48*K*AAA*
QuietComfort 19 SEER2 VS HP · source records, page 24
507 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for Q5H9V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 507 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 507 / 507 |
| EER2 · BTU/Wh | 10–13.5 | 507 / 507 |
| HSPF2 · BTU/Wh | 8.5–10 | 507 / 507 |
| Cooling capacity · BTU/h | 43,500–49,500 | 507 / 507 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,500–55,000 | 507 / 507 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,500–47,000 | 507 / 507 |
| Heating capacity at 5°F / −15°C · BTU/h | 36,000–41,500 | 507 / 507 |
| COP at 5°F / −15°C | 1.95–2.32 | 507 / 507 |
| Equipment / loop type | HP - Split System | 507 / 507 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 507 / 507 |
| Compressor staging | Continuously variable | 507 / 507 |
| Connected capability | No | 507 / 507 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X48M21A*+ furnace: *96VSN0802120B*Cold climate designationAHRI reference: 217916445 | 15.20 | 9.00 | 40000 | 2.10 | EPA 4537549 → |
EVD5X48M21A*+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 217916510 | 15.20 | 9.00 | 40000 | 2.12 | EPA 4538575 → |
EVD5X48M21A*+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 217916536 | 15.20 | 9.00 | 40000 | 2.12 | EPA 4538592 → |
EVD5X48M21A*+ furnace: *96VTN0802120B*Cold climate designationAHRI reference: 217916562 | 15.20 | 9.00 | 40000 | 2.10 | EPA 4538618 → |
EVD5X48M21A*+ furnace: *97VTN0802120A*Cold climate designationAHRI reference: 217916602 | 15.20 | 9.00 | 40000 | 2.10 | EPA 4538971 → |
EVD5X61M24A*+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 217918071 | 15.20 | 9.00 | 41000 | 2.12 | EPA 4541031 → |
EVD5X61M24A*+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 217918110 | 15.20 | 9.00 | 41000 | 2.12 | EPA 4541435 → |
ESH5X48M12A*+ furnace: OMV154L20ACold climate designationAHRI reference: 217930768 | 15.20 | 8.50 | 36600 | 2.00 | EPA 4542289 → |
ESH5X48M12A*+ furnace: *80VSL1352422B*Cold climate designationAHRI reference: 217930390 | 15.20 | 8.50 | 36600 | 2.00 | EPA 4543131 → |
ESH5X48M12A*+ furnace: OLV154F20ACold climate designationAHRI reference: 217930755 | 15.20 | 8.50 | 36800 | 2.00 | EPA 4544899 → |
ESH5X60M12A*+ furnace: *96VSN1002120B*Cold climate designationAHRI reference: 217931133 | 15.20 | 9.00 | 36800 | 2.10 | EPA 4545910 → |
ESH5X60M12A*+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 217930924 | 15.20 | 9.00 | 37000 | 2.08 | EPA 4546876 → |
ESH5X48M12A*+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 217930468 | 15.20 | 8.50 | 36600 | 2.00 | EPA 4547089 → |
ESH5X48M12A*+ furnace: *96VTN0802120B*Cold climate designationAHRI reference: 217953192 | 15.20 | 8.50 | 36800 | 2.00 | EPA 4557007 → |
ESH5X48M12A*+ furnace: *97VTN0802120A*Cold climate designationAHRI reference: 217953221 | 15.20 | 8.50 | 36800 | 2.00 | EPA 4557036 → |
EA*5X48M21A*+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 217952672 | 15.20 | 9.00 | 37200 | 2.10 | EPA 4557300 → |
EVD5X61M21A*+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 217953333 | 15.20 | 9.00 | 41500 | 2.12 | EPA 4557593 → |
EA*5X48M21A*+TDRCold climate designationAHRI reference: 217954403 | 15.20 | 9.00 | 36600 | 2.10 | EPA 4558029 → |
EA*5X60M24A*+TDRCold climate designationAHRI reference: 217954417 | 15.20 | 9.00 | 36800 | 2.10 | EPA 4558296 → |
EA*5X61M21A*+ furnace: *80CTL0451712B*Cold climate designationAHRI reference: 217952870 | 15.20 | 9.00 | 37600 | 2.08 | EPA 4558974 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →