Q5H9V48*K*AAA*
QuietComfort 19 SEER2 VS HP · source records, page 16
507 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for Q5H9V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 507 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 507 / 507 |
| EER2 · BTU/Wh | 10–13.5 | 507 / 507 |
| HSPF2 · BTU/Wh | 8.5–10 | 507 / 507 |
| Cooling capacity · BTU/h | 43,500–49,500 | 507 / 507 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,500–55,000 | 507 / 507 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,500–47,000 | 507 / 507 |
| Heating capacity at 5°F / −15°C · BTU/h | 36,000–41,500 | 507 / 507 |
| COP at 5°F / −15°C | 1.95–2.32 | 507 / 507 |
| Equipment / loop type | HP - Split System | 507 / 507 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 507 / 507 |
| Compressor staging | Continuously variable | 507 / 507 |
| Connected capability | No | 507 / 507 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X61M24A*+ furnace: *96VTN1202422B*Cold climate designationAHRI reference: 217930260 | 16.00 | 9.00 | 37600 | 2.08 | EPA 4547140 → |
EA*5X48M21A*+ furnace: *96VTN0802120B*Cold climate designationAHRI reference: 217928932 | 16.00 | 9.00 | 36800 | 2.08 | EPA 4547156 → |
ESH5X60M12A*+ furnace: *95MSU1002120A*Cold climate designationAHRI reference: 217931185 | 16.00 | 9.00 | 36800 | 2.08 | EPA 4547185 → |
ESH5X60M12A*+ furnace: *95MSU1002122A*Cold climate designationAHRI reference: 217931198 | 16.00 | 9.00 | 36600 | 2.10 | EPA 4547200 → |
EA*5X60M24A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 217929388 | 16.00 | 9.00 | 37200 | 2.10 | EPA 4547475 → |
EA*5X60M24A*+ furnace: *97VTN1202422A*Cold climate designationAHRI reference: 217929414 | 16.00 | 9.00 | 37200 | 2.08 | EPA 4547499 → |
EA*5X60M24A*+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 217952758 | 16.00 | 9.00 | 37400 | 2.08 | EPA 4557177 → |
EA*5X60M24A*+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 217952772 | 16.00 | 9.00 | 37400 | 2.08 | EPA 4557191 → |
EA*5X60M24A*+ furnace: *95MSU1002120A*Cold climate designationAHRI reference: 217952786 | 16.00 | 9.00 | 37200 | 2.10 | EPA 4557476 → |
EA*5X60M24A*+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 217952800 | 16.00 | 9.00 | 37400 | 2.10 | EPA 4558442 → |
EA*5X60M24A*+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 217952814 | 16.00 | 9.00 | 37400 | 2.08 | EPA 4558672 → |
EA*5X60M24A*+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 217952828 | 16.00 | 9.00 | 37400 | 2.10 | EPA 4558686 → |
EA*5X60M24A*+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 217952842 | 16.00 | 9.00 | 37400 | 2.08 | EPA 4558700 → |
EA*5X60M24A*+ furnace: OMV154L20ACold climate designationAHRI reference: 217952856 | 16.00 | 9.00 | 37600 | 2.10 | EPA 4558960 → |
EA*5X61M21A*+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 217952884 | 16.00 | 9.00 | 37400 | 2.10 | EPA 4559201 → |
EA*5X61M24A*+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 217952954 | 16.00 | 9.00 | 37600 | 2.08 | EPA 4560331 → |
EA*5X48M21A*+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 217952588 | 16.00 | 9.00 | 37000 | 2.10 | EPA 4561194 → |
EVD5X61M21A*+TDRCold climate designationAHRI reference: 217954613 | 16.00 | 9.50 | 40000 | 2.24 | EPA 4562128 → |
EA*5X48M21A*+ furnace: *80VSL0701716B*Cold climate designationAHRI reference: 217952546 | 16.00 | 9.00 | 37000 | 2.10 | EPA 4563484 → |
EA*5X61M24A*+ furnace: OMV154L20ACold climate designationAHRI reference: 217952996 | 16.00 | 9.00 | 37600 | 2.08 | EPA 4563649 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →