Day & Night / AIR-SOURCE HEAT PUMP

Q5H9V24*K*AAA*

QuietComfort 19 SEER2 VS HP

1,093 published source records · source checked Sep 21, 2026

SEER2 range15.2–19.5BTU/Wh
HSPF2 range8–10BTU/Wh
Cooling capacity22,200–25,400BTU/h

Each efficiency range summarizes published EPA records for Q5H9V24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 1,093 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19.51,093 / 1,093
EER2 · BTU/Wh11.5–141,093 / 1,093
HSPF2 · BTU/Wh8–101,093 / 1,093
Cooling capacity · BTU/h22,200–25,4001,093 / 1,093
Heating capacity at 47°F / 8.3°C · BTU/h22,400–25,8001,093 / 1,093
Heating capacity at 17°F / −8.3°C · BTU/h19,800–25,2001,093 / 1,093
Heating capacity at 5°F / −15°C · BTU/h20,000–22,2001,093 / 1,093
COP at 5°F / −15°C1.74–2.021,093 / 1,093
Equipment / loop typeHP - Split System1,093 / 1,093
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)1,093 / 1,093
Compressor stagingContinuously variable1,093 / 1,093
Connected capabilityNo1,093 / 1,093

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
QFVA5D3617X*Cold climate designationAHRI reference: 21869550019.508.60212001.90EPA 4683327
EVD5X37M21A*+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 21794307119.008.50214001.88EPA 4547610
EVD5X37M21A*+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 21794308619.008.50214001.90EPA 4547624
EVM5X32M17A*+ furnace: *96VSN0801716B*Cold climate designationAHRI reference: 21793787519.008.50216001.90EPA 4547636
EVD5X30M17A*+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 21794032919.008.50214001.88EPA 4547642
EVD5X30M17A*+ furnace: *80VSL0451412B*Cold climate designationAHRI reference: 21794035919.008.50214001.90EPA 4547651
EVD5X30M17A*+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 21794034419.008.50214001.90EPA 4547659
EVD5X30M17A*+ furnace: *80VSL0701412B*Cold climate designationAHRI reference: 21794037419.008.50214001.90EPA 4547688
EVD5X36M17A*+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 21794169219.008.50216001.90EPA 4547733
EVM5X32M17A*+ furnace: *95MSU0401712A*Cold climate designationAHRI reference: 21793789019.008.50214001.90EPA 4547809
EVM5X32M17A*+ furnace: *95MSU0601716A*Cold climate designationAHRI reference: 21793790519.008.50214001.90EPA 4547823
EVM5X31M17A*+ furnace: *96VSN0601716B*Cold climate designationAHRI reference: 21793727019.008.50218001.90EPA 4547871
EVM5X31M17A*+ furnace: *96VSN0801716B*Cold climate designationAHRI reference: 21793728519.008.50216001.92EPA 4547886
EVD5X37M21A*+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 21794317719.008.50214001.88EPA 4547912
EVD5X37M21A*+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 21794304119.008.50214001.88EPA 4547919
EVD5X37M21A*+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 21794305619.008.50216001.90EPA 4547936
EVM5X31M17A*+ furnace: *95MSU0401712A*Cold climate designationAHRI reference: 21793730019.008.50216001.90EPA 4548000
EVM5X25M17A*+ furnace: *80CTL0701412B*Cold climate designationAHRI reference: 21793596819.008.50216001.90EPA 4548070
EVM5X25M17A*+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 21793598319.008.50216001.90EPA 4548081
EVM5X25M17A*+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 21793599819.008.50216001.90EPA 4548097

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →