Day & Night / AIR-SOURCE HEAT PUMP

N5H9V60*K*AAA*

Performance 19 SEER2 VS HP · source records, page 9

212 published source records · source checked Sep 21, 2026

SEER2 range15.2–17.5BTU/Wh
HSPF2 range8–9BTU/Wh
Cooling capacity54,000–57,500BTU/h

Each efficiency range summarizes published EPA records for N5H9V60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 212 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17.5212 / 212
EER2 · BTU/Wh10–12212 / 212
HSPF2 · BTU/Wh8–9212 / 212
Cooling capacity · BTU/h54,000–57,500212 / 212
Heating capacity at 47°F / 8.3°C · BTU/h56,500–62,000212 / 212
Heating capacity at 17°F / −8.3°C · BTU/h48,000–50,500212 / 212
Heating capacity at 5°F / −15°C · BTU/h39,000–42,000212 / 212
COP at 5°F / −15°C1.94–2.16212 / 212
Equipment / loop typeHP - Split System212 / 212
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)212 / 212
Compressor stagingContinuously variable212 / 212
Connected capabilityNo212 / 212

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVM5X60M21A*+ furnace: *96VTN0802120B*AHRI reference: 21791886815.508.00395001.96EPA 4541234
ESH5X60M12A*+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 21793302815.508.50405002.04EPA 4542412
EA*5X61M21A*+ furnace: *95MSU1002120A*Cold climate designationAHRI reference: 21793226215.508.50410002.00EPA 4542784
EA*5X61M21A*+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 21793229215.508.50410002.00EPA 4542820
EA*5X60M24A*+ furnace: *97VTN1202422A*AHRI reference: 21793197715.509.00405002.14EPA 4543263
EA*5X60M24A*+ furnace: *97CTN1002122A*AHRI reference: 21793184215.509.00405002.12EPA 4543456
EA*5X61M21A*+ furnace: *80MSU1002120A*Cold climate designationAHRI reference: 21793209715.508.50410002.00EPA 4543516
EA*5X61M24A*+ furnace: *96VSN0802120B*Cold climate designationAHRI reference: 21793269815.508.50410002.05EPA 4543731
EA*5X60M24A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 21793188715.509.00405002.12EPA 4543971
EA*5X60M24A*+ furnace: *96VTN1202422B*AHRI reference: 21793191715.509.00405002.14EPA 4543998
EA*5X61M24A*+ furnace: *95MSU0802120A*Cold climate designationAHRI reference: 21793274315.508.50410002.00EPA 4544205
EA*5X61M24A*+ furnace: *95MSU1002120A*Cold climate designationAHRI reference: 21793275815.508.50410002.00EPA 4544219
EA*5X61M24A*+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 21793278815.508.50410002.05EPA 4544416
EA*5X61M24A*+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 21793283315.508.50410002.05EPA 4544459
EA*5X60M24A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 21793194715.509.00405002.12EPA 4544590
EA*5X61M21A*+ furnace: *80CSU0401712B*AHRI reference: 21793200715.508.50405002.00EPA 4544632
ESH5X60M12A*+ furnace: *80MSU0802120A*Cold climate designationAHRI reference: 21793307315.508.50405002.04EPA 4544943
EA*5X60M24A*+ furnace: *96CTN1002122B*AHRI reference: 21793179715.509.00405002.12EPA 4545008
EA*5X61M21A*+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 21793218715.508.50410002.00EPA 4545060
EA*5X61M21A*+ furnace: *95CSU1002122B*AHRI reference: 21793217215.508.50405002.00EPA 4545338