Heating performance & equipment details
Ranges include the 507 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 507 / 507 |
| EER2 · BTU/Wh | 10–13.5 | 507 / 507 |
| HSPF2 · BTU/Wh | 8.5–10 | 507 / 507 |
| Cooling capacity · BTU/h | 43,500–49,500 | 507 / 507 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,500–55,000 | 507 / 507 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,500–47,000 | 507 / 507 |
| Heating capacity at 5°F / −15°C · BTU/h | 36,000–41,500 | 507 / 507 |
| COP at 5°F / −15°C | 1.95–2.32 | 507 / 507 |
| Equipment / loop type | HP - Split System | 507 / 507 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 507 / 507 |
| Compressor staging | Continuously variable | 507 / 507 |
| Connected capability | No | 507 / 507 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X61M24A*+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 217929981 | 16.50 | 9.00 | 37400 | 2.08 | EPA 4542989 → |
EA*5X61M21A*+ furnace: *95MSU1002120A*Cold climate designationAHRI reference: 217929721 | 16.50 | 9.00 | 37000 | 2.10 | EPA 4543285 → |
EA*5X48M21A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 217928641 | 16.50 | 9.00 | 36800 | 2.10 | EPA 4543587 → |
EA*5X48M21A*+ furnace: *80MSU1002120A*Cold climate designationAHRI reference: 217928667 | 16.50 | 9.00 | 36800 | 2.10 | EPA 4543614 → |
EA*5X60M24A*+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 217929148 | 16.50 | 9.00 | 37200 | 2.10 | EPA 4543651 → |
EA*5X60M24A*+ furnace: *80VTL0902120B*Cold climate designationAHRI reference: 217929161 | 16.50 | 9.00 | 37200 | 2.10 | EPA 4543663 → |
EA*5X60M24A*+ furnace: *80VTL1102122B*Cold climate designationAHRI reference: 217929174 | 16.50 | 9.00 | 37000 | 2.08 | EPA 4543674 → |
EA*5X60M24A*+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 217929188 | 16.50 | 9.00 | 37000 | 2.08 | EPA 4543807 → |
EA*5X48M21A*+ furnace: *80VTL0902120B*Cold climate designationAHRI reference: 217928745 | 16.50 | 9.00 | 36800 | 2.10 | EPA 4543890 → |
EA*5X61M21A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 217929812 | 16.50 | 9.00 | 37000 | 2.10 | EPA 4544060 → |
EA*5X48M21A*+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 217928706 | 16.50 | 9.00 | 36800 | 2.10 | EPA 4544104 → |
EA*5X48M21A*+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 217928719 | 16.50 | 9.00 | 36800 | 2.08 | EPA 4544117 → |
EA*5X48M21A*+ furnace: *80VTL1102122B*Cold climate designationAHRI reference: 217928758 | 16.50 | 9.00 | 36600 | 2.10 | EPA 4544287 → |
EA*5X48M21A*+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 217928771 | 16.50 | 9.00 | 36800 | 2.10 | EPA 4544300 → |
EA*5X48M21A*+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 217928784 | 16.50 | 9.00 | 37000 | 2.08 | EPA 4544313 → |
EA*5X48M21A*+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 217928797 | 16.50 | 9.00 | 37000 | 2.08 | EPA 4544326 → |
EA*5X61M21A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 217929851 | 16.50 | 9.00 | 37000 | 2.10 | EPA 4544566 → |
EA*5X48M21A*+ furnace: *80VSL0902120B*Cold climate designationAHRI reference: 217928615 | 16.50 | 9.00 | 36800 | 2.10 | EPA 4544658 → |
EA*5X48M21A*+ furnace: *80VSL1102122B*Cold climate designationAHRI reference: 217928628 | 16.50 | 9.00 | 36600 | 2.10 | EPA 4544671 → |
EA*5X60M24A*+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 217929135 | 16.50 | 9.00 | 37200 | 2.08 | EPA 4544825 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.