N5H9V48*K*AAA*
Performance 19 SEER2 VS HP · source records, page 3
507 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H9V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 507 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 507 / 507 |
| EER2 · BTU/Wh | 10–13.5 | 507 / 507 |
| HSPF2 · BTU/Wh | 8.5–10 | 507 / 507 |
| Cooling capacity · BTU/h | 43,500–49,500 | 507 / 507 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,500–55,000 | 507 / 507 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,500–47,000 | 507 / 507 |
| Heating capacity at 5°F / −15°C · BTU/h | 36,000–41,500 | 507 / 507 |
| COP at 5°F / −15°C | 1.95–2.32 | 507 / 507 |
| Equipment / loop type | HP - Split System | 507 / 507 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 507 / 507 |
| Compressor staging | Continuously variable | 507 / 507 |
| Connected capability | No | 507 / 507 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVM5X60M21A*+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 217915919 | 16.50 | 9.50 | 40500 | 2.22 | EPA 4531949 → |
EVM5X49M21A*+ furnace: *80VSL1102122B*Cold climate designationAHRI reference: 217915411 | 16.50 | 9.50 | 40000 | 2.24 | EPA 4532213 → |
EVM5X49M21A*+ furnace: *95MSU1002122A*Cold climate designationAHRI reference: 217915645 | 16.50 | 9.00 | 40500 | 2.10 | EPA 4533191 → |
EVM5X49M21A*+ furnace: *80MSU0802120A*Cold climate designationAHRI reference: 217915437 | 16.50 | 9.00 | 40000 | 2.15 | EPA 4533237 → |
EVM5X49M21A*+ furnace: *80MSU1002120A*Cold climate designationAHRI reference: 217915450 | 16.50 | 9.00 | 40500 | 2.10 | EPA 4533286 → |
EVM5X60M21A*+ furnace: *80VTL0902120B*Cold climate designationAHRI reference: 217915932 | 16.50 | 9.50 | 40500 | 2.22 | EPA 4533502 → |
EVM5X60M21A*+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 217915971 | 16.50 | 9.00 | 40000 | 2.15 | EPA 4534820 → |
EVM5X60M21A*+ furnace: *95MSU1002122A*Cold climate designationAHRI reference: 217916075 | 16.50 | 9.00 | 40000 | 2.10 | EPA 4535311 → |
EVM5X49M21A*+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 217915372 | 16.50 | 9.00 | 40500 | 2.15 | EPA 4535500 → |
EVM5X60M21A*+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 217915802 | 16.50 | 9.50 | 40000 | 2.24 | EPA 4535738 → |
EVM5X60M21A*+ furnace: *80VSL0902120B*Cold climate designationAHRI reference: 217915828 | 16.50 | 9.50 | 40500 | 2.22 | EPA 4535766 → |
EVM5X60M21A*+ furnace: *80VSL1102122B*Cold climate designationAHRI reference: 217915841 | 16.50 | 9.50 | 40000 | 2.24 | EPA 4535780 → |
EVM5X49M21A*+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 217915476 | 16.50 | 9.50 | 40500 | 2.22 | EPA 4536274 → |
EVM5X49M21A*+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 217915489 | 16.50 | 9.50 | 40500 | 2.22 | EPA 4536286 → |
EVD5X60M21A*+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 217917132 | 16.50 | 9.00 | 40000 | 2.10 | EPA 4536388 → |
EVD5X61M21A*+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 217917583 | 16.50 | 9.00 | 41000 | 2.10 | EPA 4536875 → |
EVD5X49M24A*+ furnace: *96VTN1002122B*Cold climate designationAHRI reference: 217916898 | 16.50 | 9.50 | 40500 | 2.24 | EPA 4536886 → |
EVD5X60M21A*+ furnace: *80VTL0902120B*Cold climate designationAHRI reference: 217917093 | 16.50 | 9.50 | 40500 | 2.22 | EPA 4536921 → |
EVD5X60M21A*+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 217916963 | 16.50 | 9.50 | 40000 | 2.24 | EPA 4537256 → |
EVD5X49M24A*+ furnace: *97VTN1002122A*Cold climate designationAHRI reference: 217916937 | 16.50 | 9.50 | 40500 | 2.24 | EPA 4537465 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →