N5H9V48*K*AAA*
Performance 19 SEER2 VS HP · source records, page 18
507 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H9V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 507 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 507 / 507 |
| EER2 · BTU/Wh | 10–13.5 | 507 / 507 |
| HSPF2 · BTU/Wh | 8.5–10 | 507 / 507 |
| Cooling capacity · BTU/h | 43,500–49,500 | 507 / 507 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,500–55,000 | 507 / 507 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,500–47,000 | 507 / 507 |
| Heating capacity at 5°F / −15°C · BTU/h | 36,000–41,500 | 507 / 507 |
| COP at 5°F / −15°C | 1.95–2.32 | 507 / 507 |
| Equipment / loop type | HP - Split System | 507 / 507 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 507 / 507 |
| Compressor staging | Continuously variable | 507 / 507 |
| Connected capability | No | 507 / 507 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVM5X48M21A*+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 217914955 | 15.50 | 9.00 | 40000 | 2.10 | EPA 4533145 → |
EVM5X48M21A*+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 217914968 | 15.50 | 9.00 | 39500 | 2.10 | EPA 4533155 → |
EVM5X49M21A*+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 217915541 | 15.50 | 9.00 | 40000 | 2.15 | EPA 4533177 → |
EVD5X49M24A*+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 217916832 | 15.50 | 9.00 | 40500 | 2.12 | EPA 4533402 → |
EVD5X49M24A*+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 217916858 | 15.50 | 9.00 | 40500 | 2.12 | EPA 4533415 → |
EVM5X60M21A*+ furnace: *95MSU0802120A*Cold climate designationAHRI reference: 217916049 | 15.50 | 9.00 | 40500 | 2.12 | EPA 4533545 → |
EVM5X60M21A*+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 217915958 | 15.50 | 9.00 | 41000 | 2.12 | EPA 4533553 → |
EVM5X48M21A*+ furnace: *80VTL0902120B*Cold climate designationAHRI reference: 217915098 | 15.50 | 9.00 | 40000 | 2.10 | EPA 4533824 → |
EVM5X48M21A*+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 217915137 | 15.50 | 9.00 | 40000 | 2.10 | EPA 4533868 → |
EVM5X60M21A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 217916154 | 15.50 | 9.50 | 40500 | 2.24 | EPA 4534302 → |
EVM5X49M21A*+ furnace: *95MSU0802120A*Cold climate designationAHRI reference: 217915619 | 15.50 | 9.00 | 40500 | 2.12 | EPA 4534494 → |
EVM5X48M21A*+ furnace: *80VSL0902120B*Cold climate designationAHRI reference: 217914994 | 15.50 | 9.00 | 40000 | 2.10 | EPA 4535091 → |
EVM5X48M21A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 217915020 | 15.50 | 9.00 | 40000 | 2.10 | EPA 4535121 → |
EVM5X49M21A*+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 217915658 | 15.50 | 9.00 | 40500 | 2.12 | EPA 4535199 → |
EVM5X49M21A*+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 217915684 | 15.50 | 9.00 | 40500 | 2.12 | EPA 4535224 → |
EVM5X48M21A*+ furnace: *96VTN0802120B*Cold climate designationAHRI reference: 217915293 | 15.50 | 9.00 | 40000 | 2.10 | EPA 4535557 → |
EVM5X60M21A*+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 217915789 | 15.50 | 9.00 | 40000 | 2.10 | EPA 4535725 → |
EVD5X49M24A*+ furnace: *96VSN1202422B*Cold climate designationAHRI reference: 217916780 | 15.50 | 9.00 | 40500 | 2.12 | EPA 4536092 → |
EVD5X49M24A*+ furnace: *95MSU1002120A*Cold climate designationAHRI reference: 217916793 | 15.50 | 9.00 | 40500 | 2.10 | EPA 4536105 → |
EVM5X49M21A*+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 217915463 | 15.50 | 9.00 | 41000 | 2.10 | EPA 4536250 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.