N5H9V48*K*AAA*
Performance 19 SEER2 VS HP · source records, page 15
507 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H9V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 507 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 507 / 507 |
| EER2 · BTU/Wh | 10–13.5 | 507 / 507 |
| HSPF2 · BTU/Wh | 8.5–10 | 507 / 507 |
| Cooling capacity · BTU/h | 43,500–49,500 | 507 / 507 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,500–55,000 | 507 / 507 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,500–47,000 | 507 / 507 |
| Heating capacity at 5°F / −15°C · BTU/h | 36,000–41,500 | 507 / 507 |
| COP at 5°F / −15°C | 1.95–2.32 | 507 / 507 |
| Equipment / loop type | HP - Split System | 507 / 507 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 507 / 507 |
| Compressor staging | Continuously variable | 507 / 507 |
| Connected capability | No | 507 / 507 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X60M24A*+ furnace: *96VTN1202422B*Cold climate designationAHRI reference: 217929357 | 16.00 | 9.00 | 37200 | 2.08 | EPA 4545795 → |
ESH5X60M12A*+ furnace: *96VSN1202422B*Cold climate designationAHRI reference: 217931141 | 16.00 | 9.00 | 36800 | 2.08 | EPA 4545917 → |
EA*5X60M24A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 217929331 | 16.00 | 9.00 | 37200 | 2.10 | EPA 4545950 → |
EA*5X61M24A*+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 217930177 | 16.00 | 9.00 | 37400 | 2.08 | EPA 4546212 → |
EA*5X61M24A*+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 217930190 | 16.00 | 9.00 | 37600 | 2.08 | EPA 4546225 → |
EA*5X61M24A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 217930281 | 16.00 | 9.00 | 37400 | 2.10 | EPA 4546261 → |
EA*5X61M24A*+ furnace: *97VTN1202422A*Cold climate designationAHRI reference: 217930307 | 16.00 | 9.00 | 37600 | 2.08 | EPA 4546286 → |
EA*5X61M24A*+ furnace: *97VTN1002122A*Cold climate designationAHRI reference: 217930294 | 16.00 | 9.00 | 37000 | 2.10 | EPA 4546287 → |
ESH5X60M12A*+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 217931219 | 16.00 | 9.00 | 36800 | 2.08 | EPA 4546325 → |
EA*5X48M21A*+ furnace: *97VTN0802120A*Cold climate designationAHRI reference: 217928979 | 16.00 | 9.00 | 36800 | 2.08 | EPA 4546586 → |
ESH5X60M12A*+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 217931271 | 16.00 | 9.00 | 36800 | 2.08 | EPA 4546602 → |
EA*5X61M24A*+ furnace: *80VSL0902120B*Cold climate designationAHRI reference: 217929903 | 16.00 | 9.00 | 37200 | 2.10 | EPA 4546711 → |
ESH5X60M12A*+ furnace: *80MSU1002120A*Cold climate designationAHRI reference: 217930893 | 16.00 | 9.00 | 36600 | 2.10 | EPA 4546856 → |
EA*5X61M21A*+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 217929656 | 16.00 | 9.00 | 37200 | 2.08 | EPA 4546890 → |
EA*5X61M21A*+ furnace: *96VSN0802120B*Cold climate designationAHRI reference: 217929682 | 16.00 | 9.00 | 37000 | 2.10 | EPA 4546916 → |
EA*5X61M24A*+ furnace: *80VTL0902120B*Cold climate designationAHRI reference: 217930007 | 16.00 | 9.00 | 37200 | 2.10 | EPA 4546960 → |
EA*5X61M24A*+ furnace: *80VTL1102122B*Cold climate designationAHRI reference: 217930020 | 16.00 | 9.00 | 37000 | 2.10 | EPA 4546970 → |
ESH5X48M12A*+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 217930476 | 16.00 | 8.50 | 36600 | 2.00 | EPA 4547097 → |
EA*5X61M24A*+ furnace: *96VTN1002122B*Cold climate designationAHRI reference: 217930242 | 16.00 | 9.00 | 37000 | 2.10 | EPA 4547121 → |
EA*5X61M24A*+ furnace: *96VTN1202422B*Cold climate designationAHRI reference: 217930255 | 16.00 | 9.00 | 37600 | 2.08 | EPA 4547135 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.