N5H9V36*K*AAA*
Performance 19 SEER2 VS HP · source records, page 15
450 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H9V36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 450 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 450 / 450 |
| EER2 · BTU/Wh | 10.5–13.5 | 450 / 450 |
| HSPF2 · BTU/Wh | 7.8–9 | 450 / 450 |
| Cooling capacity · BTU/h | 33,400–37,600 | 450 / 450 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,800–37,400 | 450 / 450 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 25,200–37,600 | 450 / 450 |
| Heating capacity at 5°F / −15°C · BTU/h | 24,600–26,600 | 450 / 450 |
| COP at 5°F / −15°C | 1.9–2.18 | 450 / 450 |
| Equipment / loop type | HP - Split System | 450 / 450 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 450 / 450 |
| Compressor staging | Continuously variable | 450 / 450 |
| Connected capability | No | 450 / 450 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X42M21A*+ furnace: *80VSL0902120B*AHRI reference: 217913580 | 15.20 | 8.00 | 26200 | 2.08 | EPA 4530891 → |
EVM5X36M17A*+ furnace: *80VSL0901716B*Cold climate designationAHRI reference: 217908952 | 15.20 | 8.50 | 25600 | 2.02 | EPA 4530990 → |
EVD5X38M17A*+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 217912959 | 15.20 | 8.50 | 26400 | 2.02 | EPA 4531162 → |
EVD5X38M17A*+ furnace: *96CTN0801714B*Cold climate designationAHRI reference: 217912974 | 15.20 | 8.50 | 26200 | 2.00 | EPA 4531177 → |
EVD5X38M17A*+ furnace: *96VTN0601716B*Cold climate designationAHRI reference: 217913005 | 15.20 | 8.50 | 26400 | 2.02 | EPA 4531201 → |
EVM5X48M21A*+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 217910537 | 15.20 | 8.50 | 26200 | 2.02 | EPA 4531371 → |
EVM5X36M17A*+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 217909027 | 15.20 | 8.50 | 25800 | 2.04 | EPA 4531399 → |
EVD5X48M21A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 217914349 | 15.20 | 8.50 | 26600 | 2.00 | EPA 4531441 → |
EVD5X48M21A*+ furnace: *80VSL0902120B*Cold climate designationAHRI reference: 217914199 | 15.20 | 8.50 | 26200 | 2.02 | EPA 4531509 → |
EVD5X36M21A*+ furnace: *96VTN0802120B*Cold climate designationAHRI reference: 217912096 | 15.20 | 8.50 | 26200 | 2.02 | EPA 4531675 → |
EVD5X36M21A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 217912112 | 15.20 | 8.50 | 26200 | 2.02 | EPA 4531691 → |
EVD5X48M21A*+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 217914304 | 15.20 | 8.50 | 26400 | 2.00 | EPA 4531756 → |
EVD5X48M21A*+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 217914319 | 15.20 | 8.50 | 26200 | 2.02 | EPA 4531771 → |
EVD5X37M21A*+ furnace: *97VTN0802120A*Cold climate designationAHRI reference: 217912642 | 15.20 | 8.50 | 26400 | 2.02 | EPA 4531841 → |
EVD5X37M21A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 217912657 | 15.20 | 8.50 | 26200 | 2.02 | EPA 4531854 → |
EVD5X37M21A*+ furnace: *96VTN0802120B*Cold climate designationAHRI reference: 217912566 | 15.20 | 8.50 | 26400 | 2.02 | EPA 4531862 → |
EVD5X37M21A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 217912582 | 15.20 | 8.50 | 26200 | 2.02 | EPA 4531880 → |
EVM5X48M21A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 217910552 | 15.20 | 8.50 | 26600 | 2.00 | EPA 4532129 → |
EVD5X48M21A*+ furnace: *80VTL0902120B*Cold climate designationAHRI reference: 217914365 | 15.20 | 8.50 | 26200 | 2.02 | EPA 4532189 → |
EVD5X36M17A*+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 217911234 | 15.20 | 8.50 | 25800 | 2.04 | EPA 4532243 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →