Performance 19 SEER2 VS HP · source records, page 16
1,093 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H9V24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 1,093 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19.5 | 1,093 / 1,093 |
| EER2 · BTU/Wh | 11.5–14 | 1,093 / 1,093 |
| HSPF2 · BTU/Wh | 8–10 | 1,093 / 1,093 |
| Cooling capacity · BTU/h | 22,200–25,400 | 1,093 / 1,093 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,400–25,800 | 1,093 / 1,093 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 19,800–25,200 | 1,093 / 1,093 |
| Heating capacity at 5°F / −15°C · BTU/h | 20,000–22,200 | 1,093 / 1,093 |
| COP at 5°F / −15°C | 1.74–2.02 | 1,093 / 1,093 |
| Equipment / loop type | HP - Split System | 1,093 / 1,093 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 1,093 / 1,093 |
| Compressor staging | Continuously variable | 1,093 / 1,093 |
| Connected capability | No | 1,093 / 1,093 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X30M17A*+ furnace: *96VSN0801716B*Cold climate designationAHRI reference: 217940640 | 19.00 | 8.50 | 21400 | 1.88 | EPA 4555459 → |
EVM5X31M17A*+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 217937383 | 19.00 | 8.50 | 21800 | 1.90 | EPA 4555503 → |
EVM5X32M17A*+ furnace: *96VTN0601412B*Cold climate designationAHRI reference: 217938019 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4555631 → |
EVD5X25M17A*+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 217939595 | 19.00 | 8.50 | 21400 | 1.88 | EPA 4555694 → |
EVD5X31M17A*+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 217941216 | 19.00 | 8.50 | 21800 | 1.90 | EPA 4555794 → |
EVM5X30M17A*+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 217936763 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4555822 → |
EVD5X36M21A*+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 217942100 | 19.00 | 8.50 | 21200 | 1.88 | EPA 4555828 → |
EVD5X36M21A*+ furnace: *96VSN0802120B*Cold climate designationAHRI reference: 217942356 | 19.00 | 8.50 | 21400 | 1.88 | EPA 4555856 → |
EVD5X36M21A*+ furnace: *95MSU1002122A*Cold climate designationAHRI reference: 217942446 | 19.00 | 8.50 | 21200 | 1.88 | EPA 4555875 → |
EVD5X25M17A*+ furnace: *96VSN0801716B*Cold climate designationAHRI reference: 217939912 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4555890 → |
EVD5X38M17A*+ furnace: *80VSL0451412B*Cold climate designationAHRI reference: 217944052 | 19.00 | 8.50 | 21800 | 1.92 | EPA 4555917 → |
EVD5X38M17A*+ furnace: *80VSL0901716B*Cold climate designationAHRI reference: 217944082 | 19.00 | 8.50 | 21800 | 1.90 | EPA 4555934 → |
EVD5X36M21A*+ furnace: *80VTL1102122B*Cold climate designationAHRI reference: 217942176 | 19.00 | 8.50 | 21200 | 1.88 | EPA 4555952 → |
EVD5X36M21A*+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 217942085 | 19.00 | 8.50 | 21000 | 1.90 | EPA 4555969 → |
EVM5X30M17A*+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 217936793 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4556015 → |
EVD5X38M17A*+ furnace: *80MSU0401712A*Cold climate designationAHRI reference: 217944097 | 19.00 | 8.50 | 21600 | 1.92 | EPA 4556044 → |
EVD5X36M21A*+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 217941913 | 19.00 | 8.50 | 21200 | 1.88 | EPA 4556066 → |
EVD5X36M17A*+ furnace: OMV112K14ACold climate designationAHRI reference: 217941868 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4556103 → |
EVD5X36M21A*+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 217941883 | 19.00 | 8.50 | 21200 | 1.88 | EPA 4556118 → |