N5H8T48*K*AAA*
2-STAGE 18 SEER HP
407 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 407 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 407 / 407 |
| EER2 · BTU/Wh | 11.7–13.5 | 407 / 407 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 407 / 407 |
| Cooling capacity · BTU/h | 45,500–50,500 | 407 / 407 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 48,500–52,500 | 407 / 407 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 30,000–32,600 | 407 / 407 |
| Heating capacity at 5°F / −15°C · BTU/h | 23,800–26,600 | 407 / 407 |
| COP at 5°F / −15°C | 2.06–2.32 | 407 / 407 |
| Equipment / loop type | HP - Split System | 407 / 407 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 407 / 407 |
| Compressor staging | Two-stage | 407 / 407 |
| Connected capability | No | 407 / 407 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
FTMA5B60L0D*AHRI reference: 215560723 | 18.00 | 8.10 | 24600 | 2.32 | EPA 3982816 → |
QFVA5D6021X*AHRI reference: 218695450 | 18.00 | 8.50 | 25800 | 2.32 | EPA 4683377 → |
EVM5X49M21A*+ furnace: *80MSU0802120A*AHRI reference: 215623320 | 17.50 | 8.10 | 24400 | 2.14 | EPA 3947645 → |
EVM5X60M21A*+ furnace: *96VTN1002122B*AHRI reference: 215624041 | 17.50 | 8.10 | 24400 | 2.14 | EPA 3948047 → |
EVM5X60M21A*+ furnace: *80MSU0802120A*AHRI reference: 215623718 | 17.50 | 8.10 | 24400 | 2.14 | EPA 3948277 → |
EVD5X49M24A*+ furnace: *80MSU0802120A*AHRI reference: 215624476 | 17.50 | 8.10 | 24600 | 2.14 | EPA 3948715 → |
EVD5X60M21A*+ furnace: *96VTN1002122B*AHRI reference: 215625006 | 17.50 | 8.10 | 24400 | 2.14 | EPA 3949218 → |
EVD5X61M21A*+ furnace: *80VSL1102122B*AHRI reference: 215625032 | 17.50 | 8.50 | 24800 | 2.26 | EPA 3949243 → |
EVD5X61M21A*+ furnace: *80MSU0601716A*AHRI reference: 215625048 | 17.50 | 8.10 | 25000 | 2.12 | EPA 3949260 → |
EVD5X61M21A*+ furnace: *80MSU0802120A*AHRI reference: 215625067 | 17.50 | 8.50 | 24400 | 2.30 | EPA 3949278 → |
EVD5X61M21A*+ furnace: *80MSU1002120A*AHRI reference: 215625086 | 17.50 | 8.50 | 25000 | 2.26 | EPA 3949297 → |
EVD5X61M21A*+ furnace: *80CTL0902120B*AHRI reference: 215625116 | 17.50 | 8.50 | 25200 | 2.24 | EPA 3949328 → |
EVD5X61M21A*+ furnace: *80CTL1102120B*AHRI reference: 215625130 | 17.50 | 8.50 | 25000 | 2.24 | EPA 3949343 → |
EVD5X61M24A*+ furnace: *80VSL1352422B*AHRI reference: 215625415 | 17.50 | 8.50 | 25200 | 2.24 | EPA 3949361 → |
EVD5X61M24A*+ furnace: *95MSU1002122A*AHRI reference: 215625664 | 17.50 | 8.50 | 25000 | 2.26 | EPA 3949440 → |
EVD5X61M21A*+ furnace: *80VTL1102122B*AHRI reference: 215625163 | 17.50 | 8.10 | 24600 | 2.14 | EPA 3949464 → |
EVD5X61M21A*+ furnace: *95MSU1002122A*AHRI reference: 215625298 | 17.50 | 8.10 | 24400 | 2.16 | EPA 3949594 → |
EVD5X61M21A*+ furnace: *96VTN1002122B*AHRI reference: 215625376 | 17.50 | 8.50 | 24600 | 2.28 | EPA 3949747 → |
EVD5X61M24A*+ furnace: *80VSL1102122B*AHRI reference: 215625402 | 17.50 | 8.50 | 25000 | 2.24 | EPA 3949772 → |
EVD5X61M24A*+ furnace: *80CTL1352422B*AHRI reference: 215625475 | 17.50 | 8.50 | 24800 | 2.28 | EPA 3949808 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →