Day & Night / AIR-SOURCE HEAT PUMP

N5H8T48*K*AAA*

2-STAGE 18 SEER HP

407 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for N5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 407 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18407 / 407
EER2 · BTU/Wh11.7–13.5407 / 407
HSPF2 · BTU/Wh7.8–8.5407 / 407
Cooling capacity · BTU/h45,500–50,500407 / 407
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500407 / 407
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600407 / 407
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600407 / 407
COP at 5°F / −15°C2.06–2.32407 / 407
Equipment / loop typeHP - Split System407 / 407
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)407 / 407
Compressor stagingTwo-stage407 / 407
Connected capabilityNo407 / 407

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FTMA5B60L0D*AHRI reference: 21556072318.008.10246002.32EPA 3982816 →
QFVA5D6021X*AHRI reference: 21869545018.008.50258002.32EPA 4683377 →
EVM5X49M21A*+ furnace: *80MSU0802120A*AHRI reference: 21562332017.508.10244002.14EPA 3947645 →
EVM5X60M21A*+ furnace: *96VTN1002122B*AHRI reference: 21562404117.508.10244002.14EPA 3948047 →
EVM5X60M21A*+ furnace: *80MSU0802120A*AHRI reference: 21562371817.508.10244002.14EPA 3948277 →
EVD5X49M24A*+ furnace: *80MSU0802120A*AHRI reference: 21562447617.508.10246002.14EPA 3948715 →
EVD5X60M21A*+ furnace: *96VTN1002122B*AHRI reference: 21562500617.508.10244002.14EPA 3949218 →
EVD5X61M21A*+ furnace: *80VSL1102122B*AHRI reference: 21562503217.508.50248002.26EPA 3949243 →
EVD5X61M21A*+ furnace: *80MSU0601716A*AHRI reference: 21562504817.508.10250002.12EPA 3949260 →
EVD5X61M21A*+ furnace: *80MSU0802120A*AHRI reference: 21562506717.508.50244002.30EPA 3949278 →
EVD5X61M21A*+ furnace: *80MSU1002120A*AHRI reference: 21562508617.508.50250002.26EPA 3949297 →
EVD5X61M21A*+ furnace: *80CTL0902120B*AHRI reference: 21562511617.508.50252002.24EPA 3949328 →
EVD5X61M21A*+ furnace: *80CTL1102120B*AHRI reference: 21562513017.508.50250002.24EPA 3949343 →
EVD5X61M24A*+ furnace: *80VSL1352422B*AHRI reference: 21562541517.508.50252002.24EPA 3949361 →
EVD5X61M24A*+ furnace: *95MSU1002122A*AHRI reference: 21562566417.508.50250002.26EPA 3949440 →
EVD5X61M21A*+ furnace: *80VTL1102122B*AHRI reference: 21562516317.508.10246002.14EPA 3949464 →
EVD5X61M21A*+ furnace: *95MSU1002122A*AHRI reference: 21562529817.508.10244002.16EPA 3949594 →
EVD5X61M21A*+ furnace: *96VTN1002122B*AHRI reference: 21562537617.508.50246002.28EPA 3949747 →
EVD5X61M24A*+ furnace: *80VSL1102122B*AHRI reference: 21562540217.508.50250002.24EPA 3949772 →
EVD5X61M24A*+ furnace: *80CTL1352422B*AHRI reference: 21562547517.508.50248002.28EPA 3949808 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →