Day & Night / AIR-SOURCE HEAT PUMP

N5H8T36*K*AAA*

2-STAGE 18 SEER HP · source records, page 11

257 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,800–38,000BTU/h

Each efficiency range summarizes published EPA records for N5H8T36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 257 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17257 / 257
EER2 · BTU/Wh11.7–13257 / 257
HSPF2 · BTU/Wh7.8–8.5257 / 257
Cooling capacity · BTU/h33,800–38,000257 / 257
Heating capacity at 47°F / 8.3°C · BTU/h37,200–39,000257 / 257
Heating capacity at 17°F / −8.3°C · BTU/h23,000–24,200257 / 257
Heating capacity at 5°F / −15°C · BTU/h17,500–19,600257 / 257
COP at 5°F / −15°C1.78–2.48257 / 257
Equipment / loop typeHP - Split System257 / 257
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)257 / 257
Compressor stagingTwo-stage257 / 257
Connected capabilityNo257 / 257

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X42M21A*+ furnace: *96VSN1002120B*AHRI reference: 21563720815.208.10190002.22EPA 3955358 →
EA*5X42M21A*+ furnace: *95MSU1002120A*AHRI reference: 21563731015.208.10188002.24EPA 3955374 →
EA*5X42M21A*+ furnace: *95MSU1002122A*AHRI reference: 21563733815.208.10188002.24EPA 3955391 →
EA*5X42M21A*+ furnace: *96CTN1002122B*AHRI reference: 21563742615.208.10188002.24EPA 3955407 →
EA*5X43M21A*+ furnace: *80CSU0401712A*AHRI reference: 21563760615.208.10196002.24EPA 3955433 →
EA*5X43M21A*+ furnace: *80CSU0802120A*AHRI reference: 21563764515.208.10195002.24EPA 3955448 →
EA*5X43M21A*+ furnace: *80CTL0701716B*AHRI reference: 21563787915.208.10195002.24EPA 3955603 →
EA*5X43M21A*+ furnace: *96VSN0801716B*AHRI reference: 21563826115.208.10196002.24EPA 3955642 →
EA*5X43M21A*+ furnace: *96VTN0801716B*AHRI reference: 21563855215.208.10196002.24EPA 3955664 →
EA*5X43M21A*+ furnace: *95MSU0601716A*AHRI reference: 21563832715.208.10196002.22EPA 3955713 →
EA*5X48M21A*+ furnace: *80VSL0901716B*AHRI reference: 21563877715.208.10191002.26EPA 3955797 →
EA*5X43M21A*+ furnace: *95CSU0601716B*AHRI reference: 21563807515.208.10194002.24EPA 3955911 →
EA*5X43M21A*+ furnace: *97CMN0801714B*AHRI reference: 21563818015.208.10195002.24EPA 3955954 →
EA*5X43M21A*+ furnace: *96CTN0801714B*AHRI reference: 21563845015.208.10194002.24EPA 3956041 →
EA*5X48M21A*+ furnace: *80CSU0401712A*AHRI reference: 21563869215.208.10193002.22EPA 3956076 →
EA*5X48M21A*+ furnace: *80CSU0802120A*AHRI reference: 21563873615.208.10192002.24EPA 3956090 →
EA*5X48M21A*+ furnace: *80VSL0701716B*AHRI reference: 21563875715.208.10192002.24EPA 3956105 →
EA*5X48M21A*+ furnace: *80CTL0701716B*AHRI reference: 21563897015.208.10193002.24EPA 3956167 →
EA*5X48M21A*+ furnace: *80VTL0701716B*AHRI reference: 21563907715.208.10193002.24EPA 3956174 →
EA*5X48M21A*+ furnace: *80CTL0702120B*AHRI reference: 21563899215.208.10192002.26EPA 3956182 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →