Day & Night / AIR-SOURCE HEAT PUMP

N5H8T24*K*AAA*

2-STAGE 18 SEER HP · source records, page 4

514 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for N5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 514 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5514 / 514
EER2 · BTU/Wh11.5–14514 / 514
HSPF2 · BTU/Wh7.8–8.5514 / 514
Cooling capacity · BTU/h22,200–25,000514 / 514
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400514 / 514
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000514 / 514
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500514 / 514
COP at 5°F / −15°C1.9–2.24514 / 514
Equipment / loop typeHP - Split System514 / 514
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)514 / 514
Compressor stagingTwo-stage514 / 514
Connected capabilityNo514 / 514

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X37M21A*+ furnace: *96CTN0802120B*AHRI reference: 21564858617.508.00112002.10EPA 3719650
EVM5X31M17A*+ furnace: *80VSL0451412B*AHRI reference: 21561383217.507.80109001.98EPA 3945999
EA*5X25M17A*+ furnace: *80VSL0451412B*AHRI reference: 21564439217.508.10110002.10EPA 3957786
EA*5X25M17A*+ furnace: *80VSL0901716B*AHRI reference: 21564445117.508.10111002.10EPA 3957821
EA*5X25M17A*+ furnace: *80MSU0601716A*AHRI reference: 21564450317.508.10110002.10EPA 3957858
EA*5X25M17A*+ furnace: *80CTL0701716B*AHRI reference: 21564456817.508.10111002.10EPA 3957903
EA*5X25M17A*+ furnace: *80CTL0901716B*AHRI reference: 21564458817.508.10111002.10EPA 3957916
EA*5X25M17A*+ furnace: *80VTL0451412B*AHRI reference: 21564461317.508.10110002.10EPA 3957932
EA*5X25M17A*+ furnace: *80VTL0701716B*AHRI reference: 21564465717.508.10111002.10EPA 3957957
EA*5X25M17A*+ furnace: *95CSU0601716B*AHRI reference: 21564469317.508.10111002.10EPA 3957982
EA*5X25M17A*+ furnace: *97CMN0601714B*AHRI reference: 21564471317.508.10111002.08EPA 3957997
EA*5X25M17A*+ furnace: *97CMN0801714B*AHRI reference: 21564473417.508.10111002.08EPA 3958010
EA*5X25M17A*+ furnace: *96VTN0801716B*AHRI reference: 21564508817.508.10111002.08EPA 3958052
EA*5X25M17A*+ furnace: *96VSN0601716B*AHRI reference: 21564481417.508.10112002.08EPA 3958080
EA*5X25M17A*+ furnace: *96VSN0801716B*AHRI reference: 21564483317.508.10111002.08EPA 3958088
EA*5X25M17A*+ furnace: *95MSU0601716A*AHRI reference: 21564488417.508.10111002.10EPA 3958133
EA*5X25M17A*+ furnace: *96CTN0601714B*AHRI reference: 21564493117.508.10111002.08EPA 3958166
EA*5X25M17A*+ furnace: *96CTN0801714B*AHRI reference: 21564495317.508.10111002.10EPA 3958176
EA*5X25M17A*+ furnace: *96VTN0601716B*AHRI reference: 21564505917.508.10112002.08EPA 3958244
EA*5X25M17A*+ furnace: OMV098J12*AHRI reference: 21564513117.508.10111002.10EPA 3958281

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →