514 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for N5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 514 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5514 / 514
EER2 · BTU/Wh11.5–14514 / 514
HSPF2 · BTU/Wh7.8–8.5514 / 514
Cooling capacity · BTU/h22,200–25,000514 / 514
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400514 / 514
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000514 / 514
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500514 / 514
COP at 5°F / −15°C1.9–2.24514 / 514
Equipment / loop typeHP - Split System514 / 514
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)514 / 514
Compressor stagingTwo-stage514 / 514
Connected capabilityNo514 / 514

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
ESH5X30M12A*+ furnace: *80VSL0451412B*AHRI reference: 21565030816.507.80111002.08EPA 3963014 →
ESH5X30M12A*+ furnace: *80VSL0701412B*AHRI reference: 21565032716.508.00111002.08EPA 3963027 →
ESH5X30M12A*+ furnace: *80VSL0701716B*AHRI reference: 21565034616.507.80111002.08EPA 3963038 →
ESH5X30M12A*+ furnace: *80VSL0901716B*AHRI reference: 21565036516.507.80110002.08EPA 3963047 →
ESH5X30M12A*+ furnace: *80VSL0902120B*AHRI reference: 21565038316.508.00112002.06EPA 3963068 →
ESH5X30M12A*+ furnace: *80VSL1102122B*AHRI reference: 21565040216.508.00110002.08EPA 3963072 →
ESH5X30M12A*+ furnace: *80MSU0401712A*AHRI reference: 21565044816.508.00110002.08EPA 3963104 →
ESH5X30M12A*+ furnace: *80MSU0601716A*AHRI reference: 21565047616.507.80111002.08EPA 3963118 →
ESH5X30M12A*+ furnace: *80VTL0451412B*AHRI reference: 21565072516.507.80111002.08EPA 3963189 →
ESH5X30M12A*+ furnace: *80MSU0802120A*AHRI reference: 21565050316.507.80110002.08EPA 3963213 →
ESH5X30M12A*+ furnace: *80CTL0701412B*AHRI reference: 21565057416.508.00110002.06EPA 3963243 →
ESH5X30M12A*+ furnace: *80CTL0701716B*AHRI reference: 21565059416.507.80110002.08EPA 3963266 →
ESH5X30M12A*+ furnace: *97CMN0801714B*AHRI reference: 21565096416.507.80111002.08EPA 3963317 →
ESH5X30M12A*+ furnace: *96VSN0802120B*AHRI reference: 21565114416.508.00111002.06EPA 3963620 →
ESH5X30M12A*+ furnace: *96VSN1002120B*AHRI reference: 21565116316.507.80110002.08EPA 3963637 →
ESH5X30M12A*+ furnace: *96VSN1202422B*AHRI reference: 21565118116.507.80110002.08EPA 3963648 →
ESH5X30M12A*+ furnace: *95MSU0601716A*AHRI reference: 21565123416.507.80110002.08EPA 3963663 →
ESH5X30M12A*+ furnace: *95MSU0802120A*AHRI reference: 21565126216.508.00112002.06EPA 3963678 →
ESH5X30M12A*+ furnace: *95MSU1002120A*AHRI reference: 21565128916.508.00111002.08EPA 3963705 →
ESH5X30M12A*+ furnace: *95MSU1002122A*AHRI reference: 21565131216.507.80110002.10EPA 3963718 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →