Day & Night / AIR-SOURCE HEAT PUMP

N5H8T24*K*AAA*

2-STAGE 18 SEER HP · source records, page 13

514 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for N5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 514 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5514 / 514
EER2 · BTU/Wh11.5–14514 / 514
HSPF2 · BTU/Wh7.8–8.5514 / 514
Cooling capacity · BTU/h22,200–25,000514 / 514
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400514 / 514
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000514 / 514
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500514 / 514
COP at 5°F / −15°C1.9–2.24514 / 514
Equipment / loop typeHP - Split System514 / 514
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)514 / 514
Compressor stagingTwo-stage514 / 514
Connected capabilityNo514 / 514

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X25M17A*+ furnace: *97VTN0601412A*AHRI reference: 21799138717.008.00112002.08EPA 4566493
EA*5X37M21A*+ furnace: *97VTN0401712A*AHRI reference: 21799159517.008.00114002.06EPA 4566590
EA*5X24M14A*+ furnace: *80VSL0451412B*AHRI reference: 21564333216.508.10109002.06EPA 3956784
EA*5X24M14A*+ furnace: *80VSL0701412B*AHRI reference: 21564335116.508.10109002.06EPA 3956962
EA*5X24M14A*+ furnace: *80CTL0701412B*AHRI reference: 21564336916.508.10110002.04EPA 3956971
EA*5X24M14A*+ furnace: *80VTL0451412B*AHRI reference: 21564339416.508.10109002.06EPA 3956984
EA*5X24M14A*+ furnace: *96VSN0601412B*AHRI reference: 21564347116.508.10111002.04EPA 3957029
EA*5X24M14A*+ furnace: *96VTN0601412B*AHRI reference: 21564356616.508.10111002.04EPA 3957074
EA*5X24M17A*+ furnace: *80VSL0451412B*AHRI reference: 21564360416.508.10110002.04EPA 3957255
EA*5X24M17A*+ furnace: *80VSL0701716B*AHRI reference: 21564364016.508.10110002.04EPA 3957278
EA*5X24M17A*+ furnace: *80CTL0451712B*AHRI reference: 21564373416.508.10112002.02EPA 3957342
EA*5X24M17A*+ furnace: *80CTL0701716B*AHRI reference: 21564377616.508.10110002.04EPA 3957368
EA*5X24M17A*+ furnace: *80CTL0901716B*AHRI reference: 21564379716.508.10110002.04EPA 3957383
EA*5X24M17A*+ furnace: *80VTL0451412B*AHRI reference: 21564382016.508.10110002.04EPA 3957401
EA*5X24M17A*+ furnace: *80VTL0701716B*AHRI reference: 21564386216.508.10110002.04EPA 3957434
EA*5X24M17A*+ furnace: *95CSU0601716B*AHRI reference: 21564389616.508.00111002.05EPA 3957448
EA*5X24M17A*+ furnace: *97CMN0601714B*AHRI reference: 21564391716.508.10111002.04EPA 3957464
EA*5X24M17A*+ furnace: *97CMN0801714B*AHRI reference: 21564393816.508.10111002.04EPA 3957486
EA*5X24M17A*+ furnace: *96VSN0601716B*AHRI reference: 21564402116.508.10110002.04EPA 3957534
EA*5X24M17A*+ furnace: *96VSN0801716B*AHRI reference: 21564404116.508.10110002.04EPA 3957549

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →