D5CURAH24AAK+KSAIC0701230
Crossover Heat Pump · Crossover heat pump · source records, page 2
126 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for D5CURAH24AAK+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 126 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 126 / 126 |
| EER2 · BTU/Wh | 9.5–10 | 126 / 126 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 126 / 126 |
| Cooling capacity · BTU/h | 23,200–25,200 | 126 / 126 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 24,000–26,000 | 126 / 126 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 18,300–19,500 | 126 / 126 |
| Heating capacity at 5°F / −15°C · BTU/h | 19,000–20,000 | 126 / 126 |
| COP at 5°F / −15°C | 1.88–2.14 | 126 / 126 |
| Equipment / loop type | HP - Split System | 126 / 126 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 126 / 126 |
| Compressor staging | Continuously variable | 126 / 126 |
| Connected capability | No | 126 / 126 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X37M21A*+ furnace: *80MSU0802120A*Cold climate designationAHRI reference: 218497005 | 15.50 | 8.50 | 19000 | 1.96 | EPA 4637111 → |
EA*5X37M21A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 218496998 | 15.50 | 8.50 | 19000 | 1.96 | EPA 4637118 → |
EA*5X30M17A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 218496977 | 15.50 | 8.50 | 19400 | 1.90 | EPA 4637139 → |
EA*5X30M17A*+ furnace: *80MSU0401712A*Cold climate designationAHRI reference: 218496970 | 15.50 | 8.50 | 19400 | 1.90 | EPA 4637146 → |
EA*5X36M17A*+ furnace: *80MSU0401712A*Cold climate designationAHRI reference: 218496935 | 15.50 | 8.50 | 19300 | 1.92 | EPA 4637181 → |
EA*5X36M17A*+ furnace: *80VSL0901716B*Cold climate designationAHRI reference: 218496914 | 15.50 | 8.50 | 19400 | 1.92 | EPA 4637202 → |
EA*5X37M17A*+ furnace: *80VSL0701716B*Cold climate designationAHRI reference: 218496893 | 15.50 | 9.00 | 19300 | 2.04 | EPA 4637216 → |
EA*5X25M17A*+ furnace: *80VSL0701716B*Cold climate designationAHRI reference: 218496886 | 15.50 | 8.50 | 19100 | 1.94 | EPA 4637223 → |
EA*5X36M17A*+ furnace: *80VSL0701412B*Cold climate designationAHRI reference: 218496851 | 15.50 | 8.50 | 19400 | 1.92 | EPA 4637244 → |
EA*5X30M17A*+ furnace: *80VSL0701412B*Cold climate designationAHRI reference: 218496844 | 15.50 | 8.50 | 19400 | 1.90 | EPA 4637251 → |
EA*5X24M17A*+ furnace: *80VSL0701412B*Cold climate designationAHRI reference: 218496830 | 15.50 | 9.00 | 19600 | 1.98 | EPA 4637258 → |
EA*5X25M17A*+ furnace: *80VSL0451412B*Cold climate designationAHRI reference: 218496809 | 15.50 | 8.50 | 19100 | 1.94 | EPA 4637272 → |
EA*5X36M17A*+ furnace: *80VSL0451412B*Cold climate designationAHRI reference: 218496802 | 15.50 | 8.50 | 19300 | 1.92 | EPA 4637279 → |
EA*5X37M21A*+ furnace: *80MS(N,L)1102120A*Cold climate designationAHRI reference: 218496753 | 15.50 | 9.00 | 19100 | 2.10 | EPA 4637300 → |
EA*5X37M21A*+ furnace: *80MS(N,L)0901714A*Cold climate designationAHRI reference: 218496725 | 15.50 | 8.50 | 19000 | 1.96 | EPA 4637314 → |
EA*5X25M17A*+ furnace: *80MS(N,L)0901714A*Cold climate designationAHRI reference: 218496718 | 15.50 | 8.50 | 19100 | 1.96 | EPA 4637321 → |
EA*5X37M21A*+ furnace: *80MS(N,L)0701716A*Cold climate designationAHRI reference: 218496669 | 15.50 | 8.50 | 19000 | 1.96 | EPA 4637342 → |
EA*5X36M17A*+ furnace: *80MS(N,L)0701716A*Cold climate designationAHRI reference: 218496655 | 15.50 | 8.50 | 19400 | 1.92 | EPA 4637349 → |
EA*5X36M17A*+ furnace: *80MS(N,L)0701712A*Cold climate designationAHRI reference: 218496620 | 15.50 | 8.50 | 19300 | 1.92 | EPA 4637363 → |
EA*5X30M17A*+ furnace: *80MS(N,L)0701712A*Cold climate designationAHRI reference: 218496606 | 15.50 | 8.50 | 19400 | 1.92 | EPA 4637377 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →