D5CUHAH36AAK+KSAIC0701230
Crossover Heat Pump · source records, page 4
316 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for D5CUHAH36AAK+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 316 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17 | 316 / 316 |
| EER2 · BTU/Wh | 9.4–10.5 | 316 / 316 |
| HSPF2 · BTU/Wh | 8.1–9 | 316 / 316 |
| Cooling capacity · BTU/h | 34,200–38,000 | 316 / 316 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 37,400–40,000 | 316 / 316 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,600–26,200 | 316 / 316 |
| Heating capacity at 5°F / −15°C · BTU/h | 29,800–31,600 | 316 / 316 |
| COP at 5°F / −15°C | 1.75–1.9 | 316 / 316 |
| Equipment / loop type | HP - Split System | 316 / 316 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 316 / 316 |
| Compressor staging | Continuously variable | 316 / 316 |
| Connected capability | No | 316 / 316 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
ESH5X48M12A*+ furnace: *96VSN0802120B*Cold climate designationAHRI reference: 218492174 | 16.00 | 8.10 | 30600 | 1.75 | EPA 4635439 → |
ESH5X48M12A*+ furnace: *80VTL1102122B*Cold climate designationAHRI reference: 218492146 | 16.00 | 8.10 | 30600 | 1.75 | EPA 4635453 → |
ESH5X48M12A*+ furnace: *80MSU0802120A*Cold climate designationAHRI reference: 218492111 | 16.00 | 8.10 | 30400 | 1.75 | EPA 4635488 → |
ESH5X48M12A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 218492104 | 16.00 | 8.10 | 30400 | 1.75 | EPA 4635495 → |
ESH5X48M12A*+ furnace: *80VSL1352422B*Cold climate designationAHRI reference: 218492090 | 16.00 | 8.10 | 30400 | 1.75 | EPA 4635509 → |
ESH5X48M12A*+ furnace: *80VSL1102122B*Cold climate designationAHRI reference: 218492083 | 16.00 | 8.10 | 30400 | 1.75 | EPA 4635516 → |
FM(C,U)5Z36**AL*Cold climate designationAHRI reference: 218495039 | 16.00 | 9.00 | 31600 | 1.88 | EPA 4635988 → |
FHMA5*48L*C*Cold climate designationAHRI reference: 218495032 | 16.00 | 8.50 | 30400 | 1.84 | EPA 4635995 → |
FHMA5*42L*C*Cold climate designationAHRI reference: 218495025 | 16.00 | 8.50 | 30400 | 1.82 | EPA 4636002 → |
EA*5X36M17A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 218494810 | 16.00 | 8.10 | 31000 | 1.75 | EPA 4636093 → |
EA*5X37M17A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 218494518 | 16.00 | 8.50 | 30600 | 1.84 | EPA 4636212 → |
EA*5X37M17A*+ furnace: *80MSU0401712A*Cold climate designationAHRI reference: 218494504 | 16.00 | 8.10 | 30600 | 1.75 | EPA 4636219 → |
EA*5X37M21A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 218494382 | 16.00 | 8.50 | 30200 | 1.84 | EPA 4636268 → |
EA*5X37M21A*+ furnace: *97VTN0802120A*Cold climate designationAHRI reference: 218494368 | 16.00 | 8.50 | 30400 | 1.86 | EPA 4636275 → |
EA*5X37M21A*+ furnace: *97VTN0801716A*Cold climate designationAHRI reference: 218494355 | 16.00 | 8.50 | 30400 | 1.86 | EPA 4636282 → |
EA*5X37M21A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 218494311 | 16.00 | 8.50 | 30200 | 1.84 | EPA 4636303 → |
EA*5X37M21A*+ furnace: *96VTN0802120B*Cold climate designationAHRI reference: 218494288 | 16.00 | 8.50 | 30400 | 1.86 | EPA 4636310 → |
EA*5X37M21A*+ furnace: *96VTN0801716B*Cold climate designationAHRI reference: 218494274 | 16.00 | 8.50 | 30400 | 1.86 | EPA 4636317 → |
EA*5X37M21A*+ furnace: *95MSU1002122A*Cold climate designationAHRI reference: 218494234 | 16.00 | 8.50 | 30200 | 1.86 | EPA 4636331 → |
EA*5X37M21A*+ furnace: *95MSU1002120A*Cold climate designationAHRI reference: 218494220 | 16.00 | 8.50 | 30200 | 1.86 | EPA 4636338 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →