Heating performance & equipment details
Ranges include the 316 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17 | 316 / 316 |
| EER2 · BTU/Wh | 9.4–10.5 | 316 / 316 |
| HSPF2 · BTU/Wh | 8.1–9 | 316 / 316 |
| Cooling capacity · BTU/h | 34,200–38,000 | 316 / 316 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 37,400–40,000 | 316 / 316 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,600–26,200 | 316 / 316 |
| Heating capacity at 5°F / −15°C · BTU/h | 29,800–31,600 | 316 / 316 |
| COP at 5°F / −15°C | 1.75–1.9 | 316 / 316 |
| Equipment / loop type | HP - Split System | 316 / 316 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 316 / 316 |
| Compressor staging | Continuously variable | 316 / 316 |
| Connected capability | No | 316 / 316 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X37M17A*+ furnace: *96VSN0801716B*Cold climate designationAHRI reference: 218494601 | 15.50 | 8.50 | 30800 | 1.84 | EPA 4636184 → |
EA*5X37M17A*+ furnace: *96VSN0601716B*Cold climate designationAHRI reference: 218494587 | 15.50 | 8.50 | 30800 | 1.84 | EPA 4636191 → |
EA*5X37M17A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 218494545 | 15.50 | 8.50 | 30600 | 1.82 | EPA 4636198 → |
EA*5X37M17A*+ furnace: *80VTL0451412B*Cold climate designationAHRI reference: 218494532 | 15.50 | 8.50 | 30600 | 1.82 | EPA 4636205 → |
EA*5X37M17A*+ furnace: *80VSL0901716B*Cold climate designationAHRI reference: 218494491 | 15.50 | 8.50 | 30600 | 1.84 | EPA 4636226 → |
EA*5X37M17A*+ furnace: *80VSL0701716B*Cold climate designationAHRI reference: 218494478 | 15.50 | 8.50 | 30600 | 1.82 | EPA 4636233 → |
EA*5X37M17A*+ furnace: *80VSL0701412B*Cold climate designationAHRI reference: 218494464 | 15.50 | 8.50 | 30600 | 1.82 | EPA 4636240 → |
EA*5X37M17A*+ furnace: *80VSL0451412B*Cold climate designationAHRI reference: 218494448 | 15.50 | 8.50 | 30600 | 1.82 | EPA 4636247 → |
EA*5X37M21A*+ furnace: OMV098J12*Cold climate designationAHRI reference: 218494422 | 15.50 | 8.50 | 30400 | 1.84 | EPA 4636254 → |
EA*5X37M21A*+ furnace: *97VTN0601716A*Cold climate designationAHRI reference: 218494343 | 15.50 | 8.50 | 30400 | 1.84 | EPA 4636289 → |
EA*5X37M21A*+ furnace: *96VTN0601716B*Cold climate designationAHRI reference: 218494261 | 15.50 | 8.50 | 30400 | 1.84 | EPA 4636324 → |
EA*5X37M21A*+ furnace: *95MSU0401712A*Cold climate designationAHRI reference: 218494181 | 15.50 | 8.10 | 30400 | 1.75 | EPA 4636359 → |
EA*5X37M21A*+ furnace: *96VSN0601716B*Cold climate designationAHRI reference: 218494127 | 15.50 | 8.50 | 30400 | 1.84 | EPA 4636387 → |
EA*5X42M21A*+ furnace: *97VTN0801716A*Cold climate designationAHRI reference: 218493868 | 15.50 | 8.10 | 30800 | 1.75 | EPA 4636504 → |
EA*5X42M21A*+ furnace: *97VTN0601716A*Cold climate designationAHRI reference: 218493855 | 15.50 | 8.10 | 31000 | 1.75 | EPA 4636511 → |
EA*5X42M21A*+ furnace: *96VTN0801716B*Cold climate designationAHRI reference: 218493800 | 15.50 | 8.10 | 30800 | 1.75 | EPA 4636540 → |
EA*5X42M21A*+ furnace: *96VTN0601716B*Cold climate designationAHRI reference: 218493786 | 15.50 | 8.10 | 31000 | 1.75 | EPA 4636548 → |
EA*5X42M21A*+ furnace: *95MSU0802120A*Cold climate designationAHRI reference: 218493732 | 15.50 | 8.10 | 30800 | 1.75 | EPA 4636569 → |
EA*5X42M21A*+ furnace: *95MSU0601716A*Cold climate designationAHRI reference: 218493719 | 15.50 | 8.10 | 30800 | 1.75 | EPA 4636576 → |
EA*5X42M21A*+ furnace: *95MSU0401712A*Cold climate designationAHRI reference: 218493706 | 15.50 | 8.10 | 31000 | 1.75 | EPA 4636585 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.