Each efficiency range summarizes published EPA records for D5CUHAH30AAK+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 336 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17 | 336 / 336 |
| EER2 · BTU/Wh | 9.5–10.5 | 336 / 336 |
| HSPF2 · BTU/Wh | 8.1–9 | 336 / 336 |
| Cooling capacity · BTU/h | 28,600–31,200 | 336 / 336 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 35,800–37,400 | 336 / 336 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 20,800–21,600 | 336 / 336 |
| Heating capacity at 5°F / −15°C · BTU/h | 32,000–33,400 | 336 / 336 |
| COP at 5°F / −15°C | 1.75–2 | 336 / 336 |
| Equipment / loop type | HP - Split System | 336 / 336 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 336 / 336 |
| Compressor staging | Continuously variable | 336 / 336 |
| Connected capability | No | 336 / 336 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X36M17A*+ furnace: OMV112K14ACold climate designationAHRI reference: 218491674 | 16.00 | 8.50 | 33000 | 1.80 | EPA 4635630 → |
EA*5X36M17A*+ furnace: *95MSU0601716A*Cold climate designationAHRI reference: 218491604 | 16.00 | 8.50 | 33200 | 1.78 | EPA 4635672 → |
EA*5X36M17A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 218491505 | 16.00 | 8.50 | 33200 | 1.78 | EPA 4635728 → |
EA*5X36M17A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 218491491 | 16.00 | 8.50 | 33200 | 1.78 | EPA 4635742 → |
EA*5X36M17A*+ furnace: *80MSU0401712A*Cold climate designationAHRI reference: 218491484 | 16.00 | 8.50 | 33200 | 1.78 | EPA 4635749 → |
EA*5X36M17A*+ furnace: *80VSL0901716B*Cold climate designationAHRI reference: 218491477 | 16.00 | 8.50 | 33200 | 1.78 | EPA 4635756 → |
EA*5X36M17A*+ furnace: *80VSL0701716B*Cold climate designationAHRI reference: 218491470 | 16.00 | 8.50 | 33200 | 1.78 | EPA 4635763 → |
EA*5X36M17A*+ furnace: *80VSL0701412B*Cold climate designationAHRI reference: 218491463 | 16.00 | 8.50 | 33200 | 1.78 | EPA 4635770 → |
EA*5X37M17A*+ furnace: *97VTN0801716A*Cold climate designationAHRI reference: 218491386 | 16.00 | 9.00 | 32400 | 1.94 | EPA 4635826 → |
EA*5X37M17A*+ furnace: *97VTN0601716A*Cold climate designationAHRI reference: 218491379 | 16.00 | 9.00 | 32600 | 1.94 | EPA 4635833 → |
EA*5X37M17A*+ furnace: *96VTN0801716B*Cold climate designationAHRI reference: 218491372 | 16.00 | 9.00 | 32400 | 1.94 | EPA 4635840 → |
EA*5X37M17A*+ furnace: *96VTN0601716B*Cold climate designationAHRI reference: 218491365 | 16.00 | 9.00 | 32600 | 1.94 | EPA 4635847 → |
EA*5X37M17A*+ furnace: *95MSU0601716A*Cold climate designationAHRI reference: 218491337 | 16.00 | 9.00 | 32400 | 1.94 | EPA 4635861 → |
EA*5X37M17A*+ furnace: *96VSN0801716B*Cold climate designationAHRI reference: 218491323 | 16.00 | 9.00 | 32400 | 1.94 | EPA 4635875 → |
EA*5X37M17A*+ furnace: *96VSN0601716B*Cold climate designationAHRI reference: 218491316 | 16.00 | 9.00 | 32600 | 1.94 | EPA 4635882 → |
EA*5X37M17A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 218491238 | 16.00 | 9.00 | 32400 | 1.94 | EPA 4635924 → |
EA*5X37M17A*+ furnace: *80VTL0451412B*Cold climate designationAHRI reference: 218491231 | 16.00 | 9.00 | 32400 | 1.92 | EPA 4635931 → |
EA*5X37M17A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 218491224 | 16.00 | 9.00 | 32400 | 1.92 | EPA 4635938 → |
EA*5X37M17A*+ furnace: *80MSU0401712A*Cold climate designationAHRI reference: 218491217 | 16.00 | 9.00 | 32400 | 1.94 | EPA 4635945 → |
EA*5X37M17A*+ furnace: *80VSL0901716B*Cold climate designationAHRI reference: 218491210 | 16.00 | 9.00 | 32400 | 1.94 | EPA 4635952 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.